Pipeline monitor
Product model:PGM-1
Brief description:The ORTEC Pipe Monitor (PGM-1) is designed to monitor fluid/vapor density in nuclear reactor coolant pipes. Other applications include corrosion product activity monitoring, sulfur activation analysis in coal slurries, and stack monitoring.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
PGM-1 pipeline monitor
·Compact (maximum size 6-1/2"x20")
·Lightweight detector/dewar assembly 8-10 lbs, stainless steel shroud 25 lbs, aluminum shroud ~12 lbs
·1/4-inch Swagelok connector for cooling end cap (optional)
·Foam rubber insulation reduces impact
·External interface for in situ LN2 refilling
·Jun standard electrical connection
·Waterproof
·Be or Al end caps available
The ORTEC Pipe Monitor (PGM-1) is designed to monitor fluid/vapor density in nuclear reactor coolant pipes. Other applications include corrosion product activity monitoring, sulfur activation analysis in coal slurries, and stack monitoring. High-purity germanium (HPGe) radiation detectors are used in applications that require high-resolution gamma-ray spectroscopy measurements, such as reactor coolant pipeline monitoring. However, all germanium radiation detectors require liquid nitrogen (LN2) cooling to operate. Special dewars (thermos flasks) are designed to meet compact space requirements.
Reactor coolant pipes can reach temperatures as high as 650°F within 0.5 inches of the detector window. To ensure adequate cooling protection in this environment, the stainless steel end caps have built-in cooling tubes that circulate cold water as needed. This small but sturdy assembly is flanged to the coolant pipe.
Liquid nitrogen is refilled periodically via a separate automatic filling system attached to the rear of the housing. The LN2 Dewar has a retention time of over 16 hours. Electrical connections to the detector components (preamplifier power supply, detector, high voltage bias, high voltage cutoff, amplifier output, test pulse generator input) are made via jun specification connectors. This compact (maximum dimensions are approximately 20 inches long and 6-1/2 inches in diameter), rugged radiation detector assembly can be operated indoors or outdoors.

·Compact (maximum size 6-1/2"x20")
·Lightweight detector/dewar assembly 8-10 lbs, stainless steel shroud 25 lbs, aluminum shroud ~12 lbs
·1/4-inch Swagelok connector for cooling end cap (optional)
·Foam rubber insulation reduces impact
·External interface for in situ LN2 refilling
·Jun standard electrical connection
·Waterproof
·Be or Al end caps available
The ORTEC Pipe Monitor (PGM-1) is designed to monitor fluid/vapor density in nuclear reactor coolant pipes. Other applications include corrosion product activity monitoring, sulfur activation analysis in coal slurries, and stack monitoring. High-purity germanium (HPGe) radiation detectors are used in applications that require high-resolution gamma-ray spectroscopy measurements, such as reactor coolant pipeline monitoring. However, all germanium radiation detectors require liquid nitrogen (LN2) cooling to operate. Special dewars (thermos flasks) are designed to meet compact space requirements.
Reactor coolant pipes can reach temperatures as high as 650°F within 0.5 inches of the detector window. To ensure adequate cooling protection in this environment, the stainless steel end caps have built-in cooling tubes that circulate cold water as needed. This small but sturdy assembly is flanged to the coolant pipe.
Liquid nitrogen is refilled periodically via a separate automatic filling system attached to the rear of the housing. The LN2 Dewar has a retention time of over 16 hours. Electrical connections to the detector components (preamplifier power supply, detector, high voltage bias, high voltage cutoff, amplifier output, test pulse generator input) are made via jun specification connectors. This compact (maximum dimensions are approximately 20 inches long and 6-1/2 inches in diameter), rugged radiation detector assembly can be operated indoors or outdoors.