CIRS 002LFC IMRT chest phantom
Product model:
Brief description:The CIRS 002LFC IMRT chest model for thin film and ion chamber dosimetry is designed to solve the complex issues surrounding commissioning and comparing treatment planning systems and complete system QA from CT imaging to dose verification.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
CIRS 002LFC IMRT chest phantom
Product details
fromComplete quality check from CT imaging to dose verification
for thin film and ion chamber dosimetryThe CIRS 002LFC IMRT chest model is designed to solve the complex issues surrounding commissioning and comparing treatment planning systems and complete system QA from CT imaging to dose verification.
002LFC is an oval in shape that correctly represents the average human torso in proportion, density, and two-dimensional structure. It is 30cm long x 30cm wide x 20cm thick. The phantom is made from a proprietary tissue-equivalent epoxy material. The linear attenuation of simulated tissue is within 1% of the actual attenuation from 50 keV to 15 MeV for water and bone, and within 3% for lungs.
Tissue-equivalent interchangeable rod inserts accommodate the ionization chamber, allowing point dose measurements in multiple planes within the phantom. The location of the holes allows for verification in the most critical areas of the chest. Half of the model is divided into12 sections, each 1 cm thick to support radiographic film or GafChromic® film. Additional plugins are also available to support a variety of other detectors, including TLDs, MOSFETs, and diodes.
The phantom is easy to handle, assemble and correctly configure using a unique alignment base and fixture. The surface of the phantom is marked to facilitate laser alignment. includeCT marks to ensure accurate film to plan registration on center film.
CIRS 002LFC IMRT chest phantomFeatures
Verify heterogeneity correction
makeCTU is related to electron density
Check dose distribution in sensitive areas
Check depth dose and absolute dose
2D and 3D isovelocities
Calibrating thin films using ion chambers and other detectors*
Verify individual patient’s treatment plan
The CIRS series of IMRT phantoms are compatible with RIT 113 software and can be used for film planning analysis.
Product consultation
- Previous article:CIRS 002HN radiotherapy test phantom
- Next article:CIRS 008V dynamic phantom



Product consultation
Contact