KARRAY / PRODUCT DETAILS

Environmental radioactive radiation safety monitoring system

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Environmental radioactive radiation safety monitoring system image

Environmental radioactive radiation safety monitoring system

Product model:Iospectra® Hawk

Brief description:The Iospectra® Hawk radioactive radiation monitoring system is a system launched by Medcom for continuously monitoring the level of ionizing radiation in the environment and collecting other meteorological data. The entire system consists of a high-performance radiation probe and a host computer for radiation value monitoring, recording and automatic alarm systems. You can install the Iospectra® Hawk directly on the wall or fix it on a tripod.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

Iospectra® Hawk Environmental radioactive radiation safety monitoring system

Product introduction:

  The Iospectra® Hawk radioactive radiation monitoring system is a system launched by Medcom for continuously monitoring the level of ionizing radiation in the environment and collecting other meteorological data. The entire system consists of a high-performance radiation probe and a host computer for radiation value monitoring, recording and automatic alarm systems. You can install the Iospectra® Hawk directly on the wall or fix it on a tripod.

   withIospectra® Hawk is equipped with the Iospectra ® 1320-AO high-sensitivity, fast-response probe specially developed by Medcom. The probe consists of two independent sensors. The "pancake-style/pancake-style" Geiger-Müeller tube/Geiger-Müller tube is used to detect alpha rays in the environment. The other sensor is an energy-compensated gamma tube, which can be used to monitor beta, γ and Χ rays in the environment. The probe can be installed on Iospectra® Around the Hawk host, it can also be installed at a remote location several hundred meters away from the host. For example, you can install the Hawk host indoors and the 1320-AO probe outdoors. Of course, you can also install the entire system on a tripod and use it with solar power panels to build a complete and efficient small mobile radioactive safety monitoring station.

   The Hawk host has two data displays, which are used to display the real-time data monitored by the two sensors of the probe respectively. It has a user-defined alarm setting function. At the same time, the Hawk host*'s output and control system allows you to easily obtain monitoring data remotely in real time. At the same time, the data can be output to external control equipment to achieve various emergency handling of emergencies.

Application:

l The Iospectra® Hawk radioactive radiation monitoring system is designed for continuous monitoring and radioactive radiation safety warning. It can be used in a variety of applications including HVAC building air inlet monitoring, hospital environments, medical imaging equipment, scrap metal processing, scientific research facilities, building or warehouse entrances, etc.

l Compared with other complex monitoring systems, modular designIospectra® Hawk has the characteristics of simple overall structure and low cost. As a continuous safety monitoring eye in environments with various radiation safety hazards, Iospectra® Hawk will perform very well.

l Compared with other complex and expensive radiation monitoring systems,Iospectra® Hawk does not have isotope identification capabilities and extreme sensitivity. The optimized Iospectra ® 1320-AO probe can actively respond to changes in the radiation level of the current environment (even a slight increase) and display monitoring results within a short time (30S). The dual-sensor design also ensures that Iospectra ® 1320-AO The probe can respond quickly to various types of radiation under most extreme conditions, regardless of whether the radiation source is alpha rays or beta, gamma and x-rays.

l Iospectra® Hawk can also be used as a regional environmental radiation safety monitoring display terminal, portal radiation safety monitoring display terminal, entrance radiation safety monitoring display terminal, building radiation safety monitoring display terminal, etc. You can even install it at the air inlet of the building and connect it to the air ventilation system to automatically close the air ventilation vents in an emergency, thus protecting people in the building from the harm of external radiation substances.

Features:

Display:

2 4-digit LCD displays (including mode indicator lights), 1 for displaying counts per minute/CPM (α/β/γ/Χ ray detection), 1 for displaying radiation dose/mR/hr (γ/Χ ray)

Average period:

everyThe 3-second hand updates the display. The average level in the past 30 seconds is displayed by default. If the radiation level increases, the fastest display can be set to the average level in the past 3 seconds.

Accuracy:

0~50 mR/hr, ± 15%; 50 mR/hr~100 mR/hrjfy, ± 20%

Anti-saturation:

Radiation intensity reaches the maximum rated rangeAt 100 times, the instrument count remains at full scale

Shell:

Waterproof enclosure, tamper-resistant access panel controls, optional tamper-resistant fasteners (IP51 protection level)

Power supply:

AC wall adapter standard, built-in backup 9V lithium battery. Greater than 1000 hours of battery life, low battery indicator light.

Ground:

Provides internal lightning protection and suppression grounding connector to ensure normal operation of the system in extreme environments

Output:

Output: Detector pulses can be output to an external data logger or analyzer, alarm indicators are providedThe 12V power output port can be externally connected and activated to control external power devices. Relays are optional and can be used to activate security devices or cameras, close air inlets or water valves, lock doors, and perform other functions.

Alarm specifications:

Alarm specifications:

Audible alarm:

Custom setting volume (+83~+103dBa), 2900Hz +/- 250Hz, waterproof sensor

Visual alarm:

 Super bright red domeLED light, flash frequency 1Hz; typical intensity 1300 fL; waterproof housing

Alarm output signal:

While active,12V output - Output is zero when inactive and can provide up to 100mA to drive external relays

l Sound and light alarm function, user-defined alarm settings, external control terminal can be connected, and external equipment can be controlled when an alarm occurs.

l The sophisticated wall-mounted chassis blends well into office environments, but is also suitable for industrial and security applications.

l Cables can be connected through the wall or through the bottom panel, allowing you to easily connect and control the entire system from a remote location.

l The Iospectra® Hawk is designed with secure access panel controls to all functions and provides tamper-resistant fasteners. Through the control panel, you can easily set each sensor's alarm level, power switch, low-noise alarm, etc.

Technical parameters:

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7