American TISCH TE-5000 high flow TSP sampler
Product model:
Brief description: High flow air samplers are recommended instruments for sampling large volumes of air in a collection of TSP (Total Suspended Particulate Matter) The physical design of the sampler is based on aerodynamic principles which results in a collection of particles of 100 microns (Stokes equivalent diameter) and below The TE-5000 TSP sampler is constructed of TE-5001 anodized aluminum housing, TE-50038" x 10" stainless steel filter holder

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USATISCH TE-5000 high flow TSP sampler
Product introduction:
l High flow air samplers are the recommended instruments for sampling large volumes of airCollection of TSP (Total Suspended Particulate Matter)
l The physical design of the injector is based on this resultingCollection of particles 100 microns (Stokes equivalent in aerodynamic diameter) and below
l inTE-5000 TSP Sampling consists of TE-5001 anodized aluminum housing, TE-50038" x 10" stainless steel filter holder
l TE-5005 aluminum alloy blower motor assembly, TE-50077-day mechanical timer
l TE-5009 Continuous Flow/Pressure Recorder, and TE-5010 Automotive Voltage Control
Product features:
l Ambient air monitoring to determine quality standards relative to end-of-air particulate levels
l Combined with source-specific effects on ambient levels of suspended particlesModifications to "Wind Direction Activation"
l A source that allows sampling operations only if the condition is such
l Monitoring closed environments for relatively high levels of particulate matter, especially toxic substances
l Emission monitoring vents from large diameters, where body conditions Inspection equipment using traditional stack
Technical parameters:
Intake dust removal efficiency | Comply with Federal Regulations AddendumBEPA Code Part 50 |
flow rate | 39 CFM€"60 cubic feet (1.1~1.7mA³) |
filter media | fiberglass filter8“×10"(TE-G653) |
flow control | Motor speed voltage control/Elapsed time indicator (TE-5010) |
Motor fan | Level 2 vacuum 0.6 HP 110V/60HZ (TE-116311) 220V/50HZ (TE-116312) |
flow indicator | continuous flow/Pressure Recorder (TE-5009) |
Size | 45.5" x 22.5" x 20" sampling box, 19" x 14" x 14" lid carton |
weight | 70 pounds – sampling box, 9 lb – lid carton |
Assembly space requirements | 24" square x 53" tall |
Power requirements | Single phase with grounding,110V/60HZ or 220V/50HZ |
Motor product specifications | 110V/60HZ€" Part Number TE-116311, 2 Stage Vacuum 0.6 HP, Dual Ball Bearing Through Current Discharge |
220V/50HZ€"Part number TE-116312, 2 stage vacuum 0.6 HP, ball/oil bearing, flow discharge | |
Altitude application | Arrive10,000 feet elevation |
Ambient temperature application range | -30 to +50ºC |
Relative humidity applications | 0 - 100% |
Sampling delay start range | 0 - 7 days |
Starting current | 12 amps |
Running Ampere | 6 amps |
Product consultation