Model KR001 19-hole low contrast detail detection phantom
Product model:
Brief description:19-hole low-contrast detail detection phantom KR0011. Used for low-contrast detail resolution detection of CR and DR imaging systems. 2. Diameter 100mm, 20mm thick; 19 round holes with 1cm diameter evenly distributed on the aluminum plate.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- Application scenarios for low-contrast detail detection phantoms
- Low contrast detail detection phantom丨Product Encyclopedia
- Application of low contrast detail detection phantom
- Long pole radiation measuring instrument is an important link in the radiation protection system
- 2026 Radiation Detector Purchase and Avoidance Guide: How does KARRAY Technology solve the industry’s pain points with “technology + service”?
- Radiotherapy three-dimensional water tank is an important equipment in the field of radiotherapy
- How to choose a neutron dose rate meter? Understand the detection principle so that you will not be fooled by the parameter table
- Thermoluminescence dosimeter: an important tool for accurate radiation dose measurement
- The core of the thermoluminescent dose box is the thermoluminescent detector
- How effective is the spatial resolution test card in practical applications?
Detailed introduction
19-hole low contrast detail inspection phantom KR001
1. Used for low-contrast detail resolution detection of CR and DR imaging systems.
2. Diameter 100mm, 20mm thick; 19 round holes with 1cm diameter evenly distributed on the aluminum plate.
test card by Made of 20 mm thick aluminum plate. Circular holes with a diameter of 1 cm are evenly distributed on the aluminum plate. The depth of the holes (mm) and the contrast (including
Number within the number%) varies from 0.07 mm (0.35%) to 3.2 mm (16%) for a total of 19 round holes. They are: 0.07 (0.35%),
0.11(0.55%)、0.15(0.75%)、0.19(0.95)、0.22(1.1%)、0.26(1.3%)、0.32(1.6%)、0.36(1.8%)、
0.44(2.2%)、0.52(2.6%)、0.88(4.4%)、1.06(5.3%)、1.36(6.8%)、1.48(7.4%)、1.76(8.8%)、
2.14(10.7%)、2.5(12.5%)、2.9(14.5%)、3.2(16%)。