KARRAY / PRODUCT DETAILS

American CIRS 002H9K radiotherapy test phantom

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

American CIRS 002H9K radiotherapy test phantom image

American CIRS 002H9K radiotherapy test phantom

Product model:

Brief description:The CIRS 002H9K test phantom is constructed from a proprietary tissue-equivalent epoxy resin material. From 50kev to 15kev, the linear attenuation of simulated tissue is within 1% of the actual attenuation of bone and water. These unique materials eliminate the need for correction factors, improving accuracy and saving time. The phantom simulates the patient throughout the entire process from CT data acquisition and planning to delivery and dose verification.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

USACIRS 002H9K radiotherapy test phantom

 

USACIRS 002H9K radiotherapy test phantomProduct details
——Complete quality inspection from CT imaging to dose verification

CIRS offers a variety of IMRT models to match the most common IMRT treatment areas, such as prostate, head and neck, breast, and lung.

The CIRS 002H9K test phantom is constructed from a proprietary tissue-equivalent epoxy resin material. From 50kev to 15kev, the linear attenuation of simulated tissue is within 1% of the actual attenuation of bone and water. These unique materials eliminate the need for correction factors, improving accuracy and saving time. The phantom simulates the patient throughout the entire process from CT data acquisition and planning to delivery and dose verification.

Model 002H9K simply adjusts two rotating cylinders to select any point dose position within a circular area with a diameter of 11.2 cm. Lung and bone equivalent rods can be placed anywhere within the annular region to assess heterogeneity correction. Remove the center cylinder from the virtual body to simulate a head and neck setup.

CIRS 002H9K test phantom characteristics

ionization chamber,TLDs, MOSFETs and diodes are easily positioned using interchangeable rods

Select any point dose location by rotating the cylinder

radiographic film dosimetry– ReadyPack® and/or GafChromic® film

Placing the detector closely on the film improves film calibration

CT – Film markers ensure accurate film plan registration

Indexed surface for precise alignment

With or without heterogeneous configuration

IMRT verification system

CIRS-IMRT models are made from tissue-equivalent materials and simulate within 1%, from 50kev to 15mev, for accurate simulation from CT planning to treatment delivery. The interchangeable rod design allows the model to accommodate multiple dose measurement devices, such as ion chambers, TLDs, diodes and MOSFETs, in the same location within the model*. Model cross-section accommodates GafChromic(r) or standard off-the-shelf packaging film.

The CIRS series of IMRT phantoms are compatible with RIT 113 software and can be used for film planning analysis.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.