American CIRS 700QA CT imaging QA kit ATOM phantom
Product model:
Brief description:CIRS CT imaging QA kit is suitable for CIRS ATOM dosimetry model and CIRS 007TE tissue equivalent CT dose model, and has been widely used in CT dosimetry. The insert included in the kit is designed to study the correlation between image quality and CT dose. The kit provides various targets for the assessment of two important CT performance parameters: low-contrast detectability and spatial resolution of soft tissue and lung regions.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USACIRS 700QA CT Imaging QA Kit ATOM Phantom
Introduction:
CIRS 700QA CT Imaging QA Kit ATOM Phantom
CT quality control uses anthropomorphic phantoms
traditionalCT scanner dosimetry uses standard CTDI models, such as CIRS Model 007 CT Dose Phantom. However, more complex CT protocols and continued equipment improvements require the use of anthropomorphic phantoms of different sizes and/or ages, such as the CIRS ATOM dosimetry phantom family.
CIRS CT imaging QA kit is suitable for CIRS ATOM dosimetry model and CIRS 007TE tissue equivalent CT dose model, and has been widely used in CT dosimetry. The insert included in the kit is designed to study the correlation between image quality and CT dose. The kit provides various targets for the assessment of two important CT performance parameters: low-contrast detectability and spatial resolution of soft tissue and lung regions.
The Model 700-QA is available with four inserts: Lung, Soft Tissue - Cylindrical, Soft Tissue - Spherical, and Soft Tissue - Positive 3D Line Target. The diameters of the spheres and cylinders are chosen to provide a 2:1 volume and cross-sectional area ratio for each pair of adjacent spheres and cylinders, respectively. When ordered with ATOM® inserts can be positioned in the abdomen, liver, mediastinum and lungs.
USACIRS 700QA CT Imaging QA Suite ATOM Phantom Features:
Determining low-contrast detectability
Evaluate spatial resolution
used forATOM or CIRS 007TE Phantom
3 soft tissue inserts
1 lung inserted
USACIRS 700QA CT Imaging QA Kit ATOM Phantom Specifications:
lung insertion Overall dimensions: 1.5“Øx2"
Material:
Body: tissue equivalent epoxy lung exhalation
Cylindrical Target: Tissue Equivalent Epoxy
Diameter: 7,5,3.5,2.5,1.8 and 1.2mm
Quantity: diameter three each(3) pieces
Spherical target: Tissue equivalent epoxy resin
Diameter:10, 8, 6.5, 5, 4, 3.2, 2.5 and 2 mm
Quantity: One diameter for each(1)
soft tissue insertion - Cylindrical target | |
Overall size | 1.5“Øx2" |
Material: | |
Body: | Tissue Equivalent Epoxy Soft Tissue |
Cylindrical target: | Tissue equivalent epoxy resin - 1% and 2% HU above soft tissue |
Diameter: | 7,5,3.5,2.5,1.8 and 1.2mm |
Quantity: | Each diameter is three (3) pieces |
SOFT TISSUE INSERT - *positive 3D line pair target | |
Overall dimensions: | 1.5“Øx2" |
Material: | |
Body: | Tissue Equivalent Epoxy Soft Tissue |
*Positive 3D line target: | tissue equivalent epoxy-50 HU higher than soft tissue |
Quantity: | Five (5) |
Overall dimensions: | 5 lines x 5mm wide x 12mm deep |
LP / CM: | 6,8,10,11 and 12 |
soft tissue insertion - Spherical target | |
Overall dimensions: | 1.5“Øx2" |
Material: | |
Body: | Tissue Equivalent Epoxy Soft Tissue |
Spherical target: | Tissue equivalent epoxy resin - 1% and 2% HU above soft tissue |
Diameter: | 10, 8, 6.5, 5, 4, 3.2, 2.5 and 2 mm |
Quantity: | one for each diameter and contrast (1) |
CIRS 700QA CT Imaging QA Kit ATOM Phantom Included | |
QTY: | Component Description: |
1 | lung insertion |
1 | soft tissue insertion - Cylindrical target |
1 | soft tissue insertion - Spherical target |
1 | soft tissue insertion - *Positive 3D line-to-target |