KARRAY / PRODUCT DETAILS

German AUTOMESS 6150AD5/6150AD6 dose rate meter

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

German AUTOMESS 6150AD5/6150AD6 dose rate meter image

German AUTOMESS 6150AD5/6150AD6 dose rate meter

Product model:

Brief description:6150AD5 portable environmental

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

germanyAUTOMESS 6150AD5/6150AD6/6150ad-t/6150ad-19 dose rate meter

Product introduction:

l 6150AD5 portable environmental

l The 6150AD5 portable environmental automess supplies special cables in standard lengths from 1.25 meters, 3 meters, 10 meters, 20 meters, 75 meters and 100 meters from stock

Product radiation amount:

l Unless otherwise stated,6150AD and probes are designed for photon dose equivalent (rate) Hx; H*(10) series models with suffix "/H" or "/E" are designed for detection of environmental dose equivalent (rate); "/H" The only difference between "/E" and "/E" is their compatibility with the probe; the "/E" model probe can only be used with the 6150AD host with the "/E" type suffix, and the "/H" model probe can only be used with the "/E" type host

l Note:The difference between Hx and H*(10) is not only the level of photon energy energy response, but also the difference in display units; the following table shows the 6150AD meter and probe compatibility

Probe6150ADn, 6150ADn/H table 6150ADn/E table:

l Sievert probes are neither /H nor /E models (i.e., Hx).

l Sievert probe/H type (i.e. H*(10)) available

l Sievert Probe/Type E (i.e. H*(10)) No Yes

l pulse probe(s-1) Yes Yes

Product model differences:

l the6150ADn series refers to the series models from 6150AD1-6150AD6 (where n represents 1-6)

l 6150AD1/3/5 has the same range from up to 1Sv/h, and their difference lies in the reading method and function; 6150AD3 is an upgraded version of 6150AD1, supporting the application of software (EPROM); 6150AD5 is an upgraded version of 6150AD3, which can be matched with the 6150AD-B scintillator detector for the detection of leakage pollution; similarly, 6150AD2/4/6 has the function from up to 10mSv/h has the same range, among which 6150AD4 is an upgraded version of 6150AD2, and 6150AD6 is an upgraded version of 6150AD3, which can be matched with 6150AD-B scintillator detector; the models from 6150AD1-6150AD4 are obsolete (but are still in use, especially the models 6150AD1 and 6150AD2 with simple functions and easy operation, are affected by user favorite); the table below summarizes the basic features of all models from 6150AD1-6

6150AD5 dose rate meter (high):

l is the detection of photon radiation(gamma and

l Simulation range 1µSv/h-1000mSv/h

l Number range 0.1µSv/h-999mSv/h

l energy range 45keV-3MeV(6150AD5)

l 45keV-2.6MeV(6150AD5/H,6150AD5/ E)

l   - Hx type (compatible with all probes except /E type): 6150AD5

l   - H*(10) type (compatible with all probes except /E type): 6150AD5/H

l   - Type H*(10) (compatible with pulse probes and /E probes): 6150AD5/E

6150AD-15 GAMMA detection probe:

l High dose rate photon radiation probes for detectionGamma and X-rays, powered by 6150AD

l Simulation range 0.1mSv/h-10Sv/h

l Number range 0.01mSv/h-9.99Sv/h

l energy range 65keV-3MeV

l   - Type Hx (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-15

l   - Type H*(10) (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-15/H

l   - H*(10) type (only compatible with 6150ADn/E table): 6150AD-15/E

6150AD6 dose rate meter (low):

l is the detection of photon radiation(gamma and

l Simulation range 0.1µSv/h-10mSv/h

l Number range 0.01µSv/h-9.99mSv/h

l energy range 60keV-1.3MeV

l   - Hx type (compatible with all probes except /E type): 6150AD6

l   - H*(10) type (compatible with all probes except /E type): 6150AD6/H

l   - Type H*(10) (compatible with pulse probes and /E probes): 6150AD6/E

6150AD-18 GAMMA detection probe:

l Low dose rate photon radiation probes for detectionGamma and X-rays, powered by 6150AD

l Simulation range 0.1µSv/h-10mSv/h

l Number range 0.01µSv/h-9.99mSv/h

l energy range 65keV-1.3MeV

l   - Type Hx (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-18

l   - Type H*(10) (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-18/H

l   - H*(10) type (only compatible with 6150ADn/E table): 6150AD-18/E

6150AD-17α-β-γ detection probe:

l Wipe test probe, compatible with anyModel 6150AD dose rate meter, powered by 6150AD

l Simulation range 0.1s-1-10ks-1

l Number range 0.01s-1-9.99ks-1

6150AD-b ionization chamber scintillator probe:

l It detects photon radiation3" x 3" plastic scintillator probe; for detecting gamma and X-rays, powered by 6150AD, includes spiral probe cable

l Simulation range 10nSv/h-100µSv/h

l Number range 1nSv/h-99.99µSv/h

l energy range 23keV-7MeV(6150AD-b)

l 20keV-7MeV(6150AD-b/H, 6150AD-b/E)

l   - Hx type (compatible with 6150AD5(/H) and 6150AD6(/H) tables): 6150AD-b

l   - H*(10) type (compatible with 6150AD5(/H) and 6150AD6(/H) tables): 6150AD-b/H

l   - H*(10) type (compatible with 6150AD5(/E) and 6150AD6(/E) tables): 6150AD-b/E

6150AD-19 BETA-GAMMA Liquid Sample Probe:

l Liquid radiation detection probe, compatible with all dose rate meters, manufactured by6150AD power supply. (discontinued)

6150AD-K Surface Contamination Detection Probe:

l It's a large areaα, β, and γ ray counter tubes, compatible with all 6150AD dose rate meters, powered by 6150AD, including probe connection cables

l Simulation range approx.0.1s-1-40ks-1

l Number range approx.0.01s-1-40ks-1

6150AD-t Probe with telescopic rod:

l To detect photon radiationBeta ray probe, optional γ and

l Simulation range 0.1µSv/h-10Sv/h

l Number range 0.01µSv/h-9.99Sv/h

l energy range 65keV-1.3MeV (low dose rate counting tube)

l 65keV-3MeV (high dose rate counting tube)

l   - Type Hx (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-t

l   - Type H*(10) (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-t/H

l   - H*(10) type (only compatible with 6150ADn/E table): 6150AD-t/E

l 859.1 Wall-mounted GAMMA alarm

l for a storage typeThe device supporting the 6150AD dose rate meter has eye-catching sound and light alarm prompts, and the dose rate can be adjusted to exceed the alarm threshold.

l Installable6150AD dose rate meter and probe are attached to it (excluding 6150AD and probe), wall-mounted installation, lead-acid battery or powered by 87-250V.AC/50Hz power supply

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.