KARRAY / PRODUCT DETAILS

LB 790 10-channel alpha, beta low background counter

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

LB 790 10-channel alpha, beta low background counter image

LB 790 10-channel alpha, beta low background counter

Product model:

Brief description:LB790 can simultaneously and independently measure alpha and beta radiating radionuclides. The detection limit of low activity is approximately

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

germanyBERTHOLD LB 790 10-channel alpha, beta low background counter

Product introduction:

l The LB790 can simultaneously and independently measure alpha and beta radiating radionuclides with a detection limit of approx. Low activity

l Lower detection limit calculation regardless of spillover and calibration uncertainty

l Measurement time (sample= background), 5% error probability, background value of 0.1 alpha per minute and beta 1 CPM

l forThe AM-241 has an efficiency of 34% and the SR-90 has an efficiency of 50%

l Registration interface for detector unit connectionsLB 5330, pre-processing the measured values of the count rate for transmission to the PC via the RS-232 port and the high voltage power supply

l The tray and counting tube are surrounded by a shield, 10cm thick, standard lead bricks to reduce radiation to the environment

l Measure simultaneouslyα and β (10x sample drawer planchets diameter 60mm)

l Defender directly combats suppression of cosmic rays (countermeasures counter consistent with the above)

l 10cm lead shielding in all directions for low background performance

l Modular sample testing construction (per module2 detectors)

l Easy to service, maintain and repair

l Detector and sample drawer are one unit

l Preamplifier integrated in detector

l newWindows program AMS (Activity Measurement System Data Acquisition) for PC

Features:

l Measure simultaneously10 samples - Alpha and Beta radioactivity in freely selectable units

l Multiple systems with multiple detectors (up to4 systems) parallel connection

l Measurement time definition: either enter preset time or statistical accuracy

l Automatically stores measured background in user protocol after background subtraction

l Parameters for calibration and quality assurance of nuclide maps and other maps

l Half-life automatic correction independently adjustableAlpha and Beta channels

l Real-time display of detected activity, CPM values, statistical uncertainty, alpha and beta channels in the measurement process, and different categories of measurement ranges

l Statistical screening of outliers in measured values. outlier displaycolourized

l Stored measurement data can be displayed on the monitor and evaluated at any time

l Data analysis: stored in a history file, graphic display of process measurements (background, calibration and performance checks)

l Changes within a specified period of time can be displayed, such as the background value of a trend

l Graphical representation of the measurement cycle time diagram

l Test report compilation (e.g.Excel, Word or Access)

l Sample parameters for data transfer viaExcel table input data files and data output from LIMS or reports

Technical parameters:

Overall dimensions (with lead shielding)

850×545×320 (length x width x height, unit: mm)

Weight (lead shielded)

approx. 1200kg

Sample drawers and electronic equipment

590 × 520 × 120 (length x width x height mm)

Weight detection unit

37.5kg

Dimensions Dual Detector Module

262 × 92 × 30 (length x width x height, unit: mm)

Weight Dual Detector Module

1.55kg

Material detection module

cathode copper

Material Guard Counter

Aluminum

Electronic power supply

+15/-15 V via LB 5330

Total current consumption

250mA

Amplifier current consumption

+15 V = 8 mA / -15 V = 6 mA

connector

25 POL. SUB-D signal and power

Operating point of P-10 (typ.)

1450 V

detector window

1.5 micron Hostafan foil (0.21 mg/cm²)

typical background

< 0.1 CPM (alpha)

< 1.0 CPM (Beta)

working temperature

0°C to 50°C

relative humidity

10% to 80%, no condensation

Protection level

IP50 (according to DIN IEC 60529)

 

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.