
POMO NOVA Radioactivity Detector
Product model:
Brief description:Low background, wide dynamic range, high sensitivity, in line with GMP/GLP/CFR PART11 requirements. Optimized to meet the higher requirements of PET tracer measurement. Pomo Nova is specially designed for PET tracer radionuclides.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
POMO NOVA Radioactivity Detector
Radioactivity detector for gamma nuclear positron detection
low background
wide dynamic range
High sensitivity
conform toGMP/GLP/CFR PART11 requirements
Optimized to meet higher requirementsPET tracer measurements
Pomo Nova is specifically designed for PET tracer radionuclides. This detector is the second evolution of our radio-HPLC PET flow detector. A new flow cell design combined with new electronics achieves 10 times greater sensitivity than the first generation.
The low energy gamma ray response isResearch into PET isotopes provides unique detection capabilities and ensures low background interference. The detection limit is approximately twice that when using the classic 2x2’ iodinated Na setup.
Nuclide monitoring of radiolabeled compounds separated by chromatographic techniques has been established as one of the most advanced tools in many biochemistry-related fields. Our detector is rightImprovements in radio-HPLC flow detectors. Pomo Nova uses a high-sensitivity detector, combined with our second-generation "high positron efficiency flow cell", with low-energy gamma-ray response to provide unique detection capabilities for PET isotopes (F-18, C-11, Ga-68, N-13, Cu-64,...) or high-energy Beta (Lu-177, Y-90, I-131,...) and ensure sufficiently low background interference.
The Pomo Nova has a lead-shielded chamber inside to minimize interference from the outside environment; the housing is designed to fit the detector under a standard HPLC, just like a regular UV detector. This setup reduces the need for laboratory space, and the shorter distance from column to detector increases radiation safety and minimizes dead time, resulting in sharper peaks and better resolution.

In order to get the completeFor GMP compliance and complete documentation, we recommend Pomo Nova in combination with our chromatography software Gina X. This combines digital signal transmission and a complete integrated solution. Gina X is tailor-made for radio-HPLC applications and has special features related to typical issues and challenges of radioactive chromatography, such as half-life correction or specific radioactive background subtraction. The detector can also be used in a standalone mode if your solution allows the use of a digital-to-analog converter and provides an analog signal that can be connected to the HPLC digital-to-analog converter.
Pomo Nova uses the same Elysia Communication Protocol (ECP) as Gabi NOVA.
To ensure performance and remote diagnostics,ECP allows advanced control and diagnostics of detectors, providing you with a perfect setup documentation and enhancing your GxP tools.
![]()

Product consultation
- Previous article:miniGITA Dual/Single Radioactive Chromatography Scanner
- Next article:Safira filter tightness tester



Product consultation
Contact


