CTP700 CT performance testing phantom
Product model:
Brief description:The CTP700 Performance Phantom is designed for use with state-of-the-art CT scanners and research requiring advanced phantoms to measure their full potential. The Phantom retains many of the tests and features offered on other Catphan models, including the CTP515 low-contrast module and integrated chassis mounting system.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- This knowledge of CT dose detection phantom is worth learning
- What is the specific role of CT performance testing phantom?
- How effective is the spatial resolution test card in practical applications?
- How does the German IBA line card evaluate the resolution capability of the X-ray machine?
- Safety barriers for working in radiation environments: the practical value of personal dose alarms
- 2026 Radiation Detector Purchase and Avoidance Guide: How does KARRAY Technology solve the industry’s pain points with “technology + service”?
- Online radiation alarm is the key equipment for modern radiation protection
- Thermoluminescent personal dosimeters can be used in areas such as environmental dose monitoring
- Radiotherapy three-dimensional water tank is an important equipment in the field of radiotherapy
- Do you really know about thermoluminescent personal dosimeters?
Detailed introduction
CTP700Performance phantoms are intended for use with advancedCTScanners and research require advanced phantom measurements to reach their full potential.Phantom Retained otherCatphanModels offer many tests and features includingCTP515Low contrast modules and integrated chassis mounting system. Other test subjects have improved upon this development, including in newCTP714High-resolution module adds up to30lp/cmtest pattern, inCTP682Smaller acrylic spheres, and additional bone and lung samples have been added to the low-contrast sphere array included in the Photoreceptor Geometry Module to assist customers with theirCTImages for radiotherapy treatment planning700Also contains newCTP721Wave injector for measuring slice geometry and resolution of the scanned area. In addition, in order to solve the problem due to scannerxandyDue to possible variations in the test pattern orientation of the axes, the phantom has a new rotation bracket. This allows the mounted phantom to be45°The spacing and alignment of the pawl rotation360°, to study possible angular position-dependent results. For detailed motif information,700Performance phantom manual and data sheet.700Performance phantom test summaryCTP682 -Photosensitivity measurement (linear)-Scan slice geometry-Slice sensitivity profile
-Slice width with two wire and bead ramps-Pixel (Matrix) Dimensions-circular symmetry-Dotted line position verification-Patient Alignment System Calibration-Scan increment
-MTFAlso use wire or bead point sources-Comparing targets using a volume-averaged sphereCTP714 -High resolution measurement-up to every centimeter30Line pairCTP515 -Low contrast sensitivity
-Comparing subslice and superslice low contrast sensitivityCTP721,CTP723 -Harmonics and intensity distribution of wave insertionCTP712
-spatial uniformity-Noise (accuracy)
Product consultation
- Previous article:CTP500 CT performance phantom
- Next article:RGRMS-2016 CT imaging performance testing phantom



Product consultation
Contact