KARRAY / PRODUCT DETAILS

Body Counting Body Membrane Phantom (Simulation)

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Body Counting Body Membrane Phantom (Simulation) image

Body Counting Body Membrane Phantom (Simulation)

Product model:

Brief description:ORTEC Whole Body Counter Body Membrane Phantom (Analog) is suitable for calibrating StandFASTII standing counters, traditional chair counters or any other counter designed for human counting

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC Phantom for Body Counter
The ORTEC Whole Body Counter Body Membrane Phantom (Analog) is suitable for calibrating StandFAST™ II standing counters, traditional chair counters, or any other counter designed for human counting.
  • information +

    • Download link Phantom brochure
    • Download link Phantom Brochure (A4)
  • More information +


    Phantom is made of plastic material and is designed to simulate the gamma ray scattering properties of human tissue. Source locations are used to represent the location of certain body organs.

    The rectangular design provides an economical and adequate representation of the human torso. The design is used to simulate the attenuation of gamma rays from internal sources and the scattering or attenuation of gamma rays from external sources.

    The Phantom is constructed from detachable and interlocking parts for easy movement and positioning, and can be conveniently split into two halves. The "neck" piece designed specifically for the thyroid calibration source is also removable and interlockable for reproducible positioning. The "legs" are independent of each other, allowing the phantom to be placed in the StandFAST II.

    The calibration source chamber is designed to accommodate many source manufacturers' standard 1-liter WBC calibration standards. Calibration sources can be inserted or removed without moving the phantom. Insert the lung source from the top by removing the plug. Insert the gastrointestinal source by removing the anterior part of the lower part.

    The overall dimensions of the phantom comply with Internal Radiation Dose (MIRD) Committee guidelines. (See MIRD Brochure No. 5, Supplement 3).

  • Ordering information +


    Model

    Description

    Phantom

    whole body counter body membranePhantom(simulation). Use polyethylene material to simulate95% of people.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.