KARRAY / PRODUCT DETAILS

MPC-1000-GF manual sample counter

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

MPC-1000-GF manual sample counter image

MPC-1000-GF manual sample counter

Product model:

Brief description:2in

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC MPC-1000-GF Manual, Alpha Beta Counting Sample Changer
  • 2 in. (5.1 cm) standard diameter
  • Hemispherical flow detector without window or with bed
  • cosmic ray coincidence detector
  • Gas leak detection
  • low background counter
  • touch screen
  • Gas protection
  • information +

    • Download link Alpha/Beta Manual Counting System Brochure
    • Download link α/β Manual Counting System Brochure (A4)
  • More information +


    The MPC-1000-GFW and MPC-100-GFL single-channel manual sample change low background counters are high performance low background counters. This type of counter provides new laboratories with a way to achieve low background alpha/beta measurement capabilities. It can be upgraded when the sample volume increases and a multi-detector system or automatic counting system is required to improve the measurement capability. The MPC-100-GFL counter equipped with a windowless gas detector provides the highest detection efficiency for low-energy Beta ray detection and alpha particle detection. Each counter can run programs and QC controls developed on DUO Express software, and the program can be transferred to the instrument via the PIC connection cable.
  • Specifications +


    Performance
    typical background
    Alpha 0.05 cpm (guaranteed value 0.1 cpm)
    Beta 0.7 cpm (guaranteed value 0.9 cpm)
    Typical efficiency 
      MPC-1000-GFW
    (with window) 
    MPC-1000-GFL
    (no window) 
    210Po 40% 45%
    241Am 40% 45%
    230Th 40% 45%
    90Sr/90Y 55% 55%
    99Tc 35% 45%
    137Cs 40% 45%
    crosstalk
    Alpha-Beta <0.1%
    Beta-Alpha <0.1%


    Equipment parameters
    Sample probe 2.25 in. (5.7 cm) diameter, hemispherical flow detector
    detector window MPC-1000-GFW: Aluminum film, 80 µg/cm2
    MPC-1000-GFL: No window
    Coincidence detector 1 large area air flow coincidence detector
    working gas MPC-1000-GFW: P-10, 60 cc/min,10 psi
    MPC-1000-GFL: P-10, 150 cc/min,10 psi
    Gas-PRO P-10 Gas Leak Continuous Monitoring System
    shield 4 in. (10 cm) low background lead
    Sample size 2 in (5.1 cm) diameter round, 1/8, 1/4, or 5/16 in (3.2, 6.3, or 7.9 mm) deep 
    Measurement mode Only Alpha is measured, Alpha/Beta are measured simultaneously
    interface touch screen
    Data export RS-232, USB
    Power supply 117 V ac, <0.2 A, 50/60 Hz
    230 V ac, <1.0 A, 50/60 Hz
    environment 10–40 °C (50–104 °F)
    20%–90% humidity, no condensation
    Size 23 x 24 in. (58.4 x 61 cm)
    weight 380 lb (172 kg)
  • Ordering information +


    Model Description
    ORT-MPC-1000-GFL Windowless, manual sample change, single channel low background counter
    ORT-MPC-1000-GFW Manual sample change, single channel low background counter
    Optional  
    PIC-120-0011 Cart
    PIC-140-0115SS Steel Carrier (set of 10), 1/8 in., 1/4 in., or 5/16 in.
    PIC-700-0007 Planchet, 2 inch x 1/8 inch, set of 100
    PIC-700-0008 Planchet, 2 inch x 1/4 inch, set of 100
    PIC-700-0009 Planchet, 2 inch x 5/16 inch, set of 100
    ORT-Vista 2000 Radiochemical application software

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.