ORTEC FRAM Advanced Isotopic Ratio Analysis Software for HPGe and CdTe Detector Gamma-Ray Radiation Spectra
  • FRAM analyzes Pu and a range of heterogeneous samples containing Pu, Am, U and other nuclides including 242Pu
  • withLaBr3、CZTand high-purity germanium (includeORTEC DetectiveandTrans-SPECSeries) radiation detectors operate together
  • Can read N42 format files
  • No calibration standards required
  • Suitable for shielded samples
  • Choose from the large number of samples/geometry provided or add more types
  • Ability to automatically analyze samples with unknown characteristics
  • Can easily access the command line operation mode of other application systems
  • automatic readingORTEC.chn,ORTEC.spc,Canberra.cnf,Canberra.mca, IAEA.speandASCII.txtFile
  • Can convert spectra from one energy calibration to a different energy calibration and convert multiple spectra from one format to another
  • Compatible with 64-bit and 32-bit Windows systems
  • Significant enhancements compared to previous versions

FRAM analysis consists of germanium,LaBr3orCZTRadiation detectors measure the gamma ray spectrum of materials containing plutonium, uranium, or mixed materials and quantify the distribution of plutonium or uranium isotopes, 241Am, and other transuranic isotopes (including uranium in mixed uranium-plutonium oxides) that contribute measurable gamma rays to the spectrum. These can also be quantified relative to plutonium. FRAM analyzes the spectrum of only uranium species and quantifies the uranium isotope distribution. These measurements can be performed on samples of any size, geometry, and physical and chemical composition.
  • More information +


    Fixed energy response function analysis with multiple efficiencies(FRAM)Code for high purity germanium(HPGe)detector, now, new6.1version,FRAM can be used forLaBr3andCZTModerate resolution gamma ray spectrometer(MRGS)detector.LaBr3andCZT DetectiveThe detector can operate at room temperature, is more compact, and is easy to use and maintain. With version 6.1FRAM, these detectors are now capable of isotope analysis of uranium and plutonium samples, which is very useful in the security field.

    FRAM V6.1yes2013released inV5.2major upgrade. In addition to increasingLaBr3andCZTSpectral analysis capabilities,FRAM V.6.1It also improves usability, sustainability, compatibility, maintainability, etc.



    Advanced isotope abundance analysis software for HPGe gamma ray spectroscopy
    • Analyze Pu and a variety of heterogeneous samples containing Pu, Am, U and other nuclides, including 242 Pu。
    • Available withLaBr3、CZTandHPGe explorationrun together with the detector, includingORTEC exploredetector andtrans-SPECSeries detectors
    • Can read files in N42 format
    • Operates with a single HPGe detector, including ORTEC Detective & trans-SPEC capable family.
    • No calibration standards required.
    • Use shielding body.
    • Choose from a wide range of provided samples/geometry, or add more types.
    • Automatic analysis function for samples with unknown characteristics.
    • Command line mode of operation allows easy incorporation into other applications.
    • automatic readingORTEC 'chn ',ORTEC 'spc ', Canberra' cnf ', Canberra' mca ',IAEA 'spe 'andASCII 'txt 'File
    • Convert spectra from one energy calibration to another and convert multiple spectra from one format to another
    • Windows 64-bit and 32-bit compatible.
    • Significant improvements over previous versions.

    FRAM code has been evolving at Los Alamos National Laboratory since the mid-1980s. It analyzes the use of germanium,LaBr3orCZTDetector, which acquires gamma-ray spectra from items containing plutonium or uranium or both, and quantifies the distribution of plutonium or uranium isotopes. 241 Am and other transuranic isotopes (including uranium in mixed uranium-plutonium oxides) also contribute measurable gamma rays to the spectrum, which can also be quantified relative to plutonium.

    It also analyzes the spectra of materials containing only uranium and can quantify the uranium isotope distribution. These measurements can be made on samples of any size, geometry and physical and chemical composition.

    Easy-to-use Windows user interface
    ORTEC FRAM is a member of the ORTEC CONNECTIONS family of products. It operates within the ORTEC CONNECTIONS spectrometer architecture, providing greater flexibility in the choice of MCA hardware, including the DSPEC 50/50A and DSPEC 502/502A digital spectrometers and integrated spectrometers such as the Detective, trans-SPEC and IDM series.

    The highly graphical FRAM user interface conforms to Windows conventions and is easy to use. Version 5.1 features a new look that provides a single interface for all data display for simplicity. A single dialog bar controls all aspects of spectrum and results display, allowing users to easily verify the quality of their data or analysis without leaving the main FRAM window.

    FRAM provides acquisition control for all MCA hardware supported by ORTEC CONNECTIONS. The ORTEC MAESTRO-Pro MCA software program is used for hardware system setup before use and can be removed from the PC to protect the MCB from changes.

    FRAM analysis capabilities

    Sample type
    The versatility of FRAM and its ability to analyze a variety of samples stems from its reliance on universal analytical algorithms. The specific information needed to guide the analysis is encoded as a set of parameters and stored in a database. This information includes the regions and peaks to be examined, the isotopes used in the analysis, and special information for performing a variety of diagnostic tests on the spectrum. For well-characterized "regular" analysis samples, a single analysis parameter set can be easily constructed; for less well-known samples, an automatic mode is provided in which the sample parameter set is determined iteratively in an automated manner.
    FRAMversion6.1The parameter set in is the same asFRAMParameter sets from earlier versions are backward compatible.

    Analytical methods
    FRAM analyzes peaks from plutonium or uranium gamma-ray spectra. The spectrum contains information from plutonium isotopes 238 Pu Zhi 241 Pu, 241 The peak of Am, and often other isotopes such as 235 U or 237 Np. FRAM combines this information to produce isotope ratios that are independent of sample size, shape, physical and chemical composition, measurement geometry and container characteristics. Results are obtained using only spectral data and known fundamental nuclear constants. Calibration using standards is not required.

    Peak Area Determination
    FRAM uses a response function method to determine all peak areas, fitting a Gaussian with a single exponential on the low energy side to simulate the gamma ray peak shape and using a Lorentz model to model the X-ray peak.

    relative efficiency
    FRAM uses separate efficiency curves for each isotope. This allows it to measure the specific power of high-temperature chemical residues, with biases that can be reduced by up to ten times from analyzes that do not use multiple efficiency curves.

    FRAM's multiple efficiency characteristics can also be used for other heterogeneous samples. The physical and chemical properties of the sample may not be uniform or even unknown. Items may contain a mixture of solids and powders, and as long as the plutonium is isotopically homogeneous, there will be no ill effects. Physical and empirical efficiency models are provided.

    Isotope analysis  
    The method used is to find a least squares solution to a set of linear equations including peak area, relative efficiency and isotopes as unknowns. This method allows the use of multiple peaks in the analysis, thereby increasing measurement accuracy.

    Analysis Parameters Database
    The analysis parameter database is very important in terms of the power and flexibility of FRAM. These parameter sets are divided into five categories: peak fitting parameters, gamma ray peaks to search for, energy regions to search for, isotopes to use, and special application constants. Can easily accommodate multiple parameter sets.

    Automatic analysis function
    The automatic analysis function in FRAM allows spectra to be automatically reanalyzed based on current results, and parameters to be changed. Automated analysis can be started from any parameter set and used with plutonium and uranium in all energy ranges. Users are free to program analyzes (via application constants in parameter sets) to determine material properties such as: shielding, MOX, plutonium burnup, uranium enrichment, interfering isotopes or heterogeneity. For example, after analyzing the middle energy region (120 – 500 keV) of the plutonium spectrum, it can examine the lower energy (~100 keV) and higher energy (~700 keV) regions to see if those are more favorable.

    Plutonium or uranium analysis
    It is possible to set parameter sets for uranium (only) spectra. In this case, the different isotopes are calculatedAbundance, and the format of the summary is different.

    estimate 242Pu
    242 The estimation of Pu is done using a correlation model using industry standard formulas with user specified parameters. Their values ​​can be stored in any parameter set used for analysis. This model works for most commonly used correlations 242Pu.

    Decay correction for isotope fractions
    For samples at least 5 years old, 241 The 14.35 year half-life of Pu can lead to 242 Significant changes in the Pu part, if not calculated, can result in 239 4% in Pu scoreleft and rightof(relative) error.

    FRAM can attenuate and correct the isotope composition of Pu and Am.


    Command line operation mode
    The command line operating mode is suitable for users who wish to incorporate FRAM into their own applications. This mode allows the user to create a very simple interface for the FRAM analysis engine.

    Measure - Compare Options
    This option allows the user to directly compare analysis results with attenuation-corrected declared values. The difference between the measured and declared values ​​is expressed as the standard deviation of the measured and declared values.

    FRAM V6.1 analysis improvements

    • Measure | Sum dialog: several spectra can be superimposed
    • Measure | Convert dialog box:Convert spectra from one energy calibration to another. Can also be used to convert multiple spectra from one format to another
    • Measure|Widen dialog box:Smooth or broaden spectrum
    • Ability to use background spectrum to subtract peak background
    • measuring|Get and measure|Measure centerMCAAdd new detector to combobox/MCA“instantaneous simulation”. The detector will immediately generate a spectrum from the main spectrum. it is consistent with the existing“Simulation”MCASomewhat different, the latter generates a spectrum from the main spectrum, but the data is updated in the same way as using a real detector/MCAThe actual data collection is done in a similar way
    • U235total peak correction forXUranium analysis in the ray region
    • Fluorescent X-ray Uranium/Plutonium Ratio
    • Add a quadratic step background
    • Limit/The ability to constrain the shape of the efficiency curve
    • When the peakFWHMgreater than32channel(Default)when,FRAMThe peak will be ignored and will not be fitted
    • Fitting parameters”in the dialog boxFWHMThe formula and the tail formula change from channel-dependent tokeV, making them independent of energy calibration
    • Extended tail model for better fitCZTThe large tail of the spectral peak
    • Physically heterogeneous efficiency models now use true heterogeneous models or adopt1/Model of energy factors. Empirical heterogeneous efficiency models still use1/energy factor
    • real real time and real time
    • force“secondaryBackground”concave downward

    Germanium Detector Requirements
    FRAM can perform complete isotope analysis using a single plane or a single coaxial detector. The benefits of being able to operate with a single HPGe detector are clear: cost, space, convenience, ease of use and reliability. When used with "traditional" single plane detectors, it is often (but not always) used to collect and analyze data in the 120 and 420 keV range.

    The visible energy range for use with coaxial detectors is 0 - 1024 keV. A variety of analysis modes are available across this wide range of data. if120KeV - 200 keV range is available, FRAM will be in120KeV - 450 keVanalyzed within the scope. If this is not possible (for example, if the sample is shielded or in a thick-walled container), FRAM can still obtain a complete analysis using only gamma rays above 200keV from a single coaxial detector.

    The size of the detector depends on the application expected to be encountered. If all the items being measured are unshielded or "thin-walled", then a flat detector is usually the detector of choice. If you encounter shielded containers, thick-walled containers, or a mixture of all container types, a single coaxial detector is ideal. ORTEC Safeguards series HPGe detectors are highly recommended.

    ORTEC Detective and trans-SPEC portable spectrometers have proven to be very effective in many applications. FRAM software includes ORTEC Detective's start-up analysis parameter set.

    Password protection and security
    Access control systems in FRAM store a list of users, their passwords and the access rights granted to them. Three items listed in the Edit menu are protected by this mechanism: the Parameters option, the General Defaults option, and the User List. When all these options are running, the user will be asked for a name and password. If the security check fails, control returns to the main menu.

    Output displays and lists
    Three levels of output display (short results, intermediate results and long results) can be selected in the FRAM dialog bar and all analysis results displayed in the FRAM window. After each analysis, a screen copy of the short results is automatically sent to the monitor.

    Prerequisites
    As a member of the CONNECTIONS family, FRAM-BW can run normally on any system that supports CONNECTIONS compatible hardware. The software runs under all currently supported Windows operating systems. Windows 7 64-bit hardware compatibility applies to all ORTEC instruments using USB and TCP/IP connections. Windows 7 and XP 32-bit operating systems also support these instruments as well as other legacy hardware.
  • information +

    • Download link FRAM Brochure
    • Download link FRAM brochure (A4)
    • Download link FRAM manual
  • Ordering information +


    Model

    Description

    FRAM-BW

    Version 6.1 gamma ray isotope analysis software.includeMAESTRO-PRO MCASimulation software.