KARRAY / PRODUCT DETAILS

R Series Ruggedized Partially Depleted Silicon Radiation Detectors

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

R Series Ruggedized Partially Depleted Silicon Radiation Detectors image

R Series Ruggedized Partially Depleted Silicon Radiation Detectors

Product model:

Brief description:Main application: Charged particle spectroscopy measurements in vacuum or air under ambient light; can be cleaned

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

Main applications
For charged particle spectroscopy measurements in vacuum or air under ambient light; can be cleaned.
  • information +

    • Download link R Series Brochure
    • Download link R series brochure (A4)
  • Installation layout +


    Mounting base must be specified when ordering

    A
     This is a "ring mount"; i.e. the silicon die is on its ring and there are no output connectors. 

    B  backMicrodotconnector.

    C  backBNCconnector.

    T  sidewaysMicrodot;No adjustable screws.

    Dimensions are in millimeters.

    §Only built intoMicrodotinside the connector.


    Detector size (mm2)

    W (nominal)
    Atype  Btype afterMicrodot Ctype afterBNC   Ttype§transmission
    X Y  X Y Z X Y Z X Y Z
     050  8.0 15.2 3.7
    16.7 12.3 7.1 16.7 12.3 15.9 19.4 7.9 9.9
     150  13.8 22.0 3.7
    23.6 12.3 7.1 23.6 12.3 15.9 26.1 7.9 9.9
     300  19.5 27.1 3.7
    28.6 12.3 7.1 28.6 12.3 15.9 31.6 7.9 9.9
     450 23.9 30.5 3.7
    32.0 12.3
    7.1 32.0 12.3
    15.9 34.8 7.9 9.9
     600  27.6 34.1 3.7 36.1 12.3 7.1 36.1 12.3 15.9 38.4 7.9 9.9
     900  33.9 43.2 3.7 45.2 12.3 7.1 45.2 12.3 15.9      
     2000 51.0      65.5 12.3 7.1 65.5 12.3 15.9      
     Tolerance ±0.5 ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3 ±0.3 ±0.3
  • Ordering information +


    Mount must be specified when ordering.

    B mounts are provided unless otherwise stated.

    *B mounts supplied unless otherwise specified with appropriate letter prefix. Other areas, thicknesses and configurations available on special order.

    **The first three digits of the model number indicate when using standard ORTEC electronics and a 0.5-μs shaping time constant.241AM, total system resolution FWHM of 5.486-MeV α. Beta resolution measures FWHM using a pulse generator.

    Note:CompatibleAlphaKit of detectors:ENS-Series(Installation and testing included with purchase of new system)、ENS8Series(new system8Package spare parts)、BInterfaceULTRA-ASand low backgroundR seriesDetector model warranty andAlphaKit products(DUO、MEGA、ARIA、ENSEMBLE)Compatible. All other detectors require special approval to ensure compatibility and specifications.


    Effective area (mm2)

    Guaranteed resolution**(keV)

    Minimum resolution thickness100 μm

    Minimum resolution thickness300 μm

    α

    β

    Model

    Model

    50

    15
    17

    7
    8

    R-015-050-100
    R-017-050-100

    R-015-050-300
    R-017-050-300

    150

    16
    19

    10
    11

    R-016-150-100
    R-019-150-100

    R-016-150-300
    R-019-150-300

    300

    19
    21

    13
    15

    R-019-300-100
    R-021-300-100

    R-019-300-300
    R-021-300-300

    450

    20
    24

    14
    19

    R-020-450-100
    R-024-450-100

    R-020-450-300
    R-024-450-300

    600

    25
    33

    17
    28

    R-025-600-100
    R-033-600-100

    R-025-600-300
    R-033-600-300

    900

    30
    40

    25
    35

    R-030-900-100
    R-040-900-100

    R-030-900-300
    R-040-900-300

    2000

    50
    60

    45
    55

    R-050-2000-100
    R-060-2000-100

    R-050-2000-300
    R-060-2000-300




    Effective area (mm2)

    Guaranteed resolution**(keV)

    Minimum resolution thickness500 μm

    α

    β

    Model

    50

    15
    17

    7
    8

    R-015-050-500
    R-017-050-500

    150

    16
    18

    10
    11

    R-016-150-500
    R-018-150-500

    300

    19
    21

    13
    15

    R-019-300-500
    R-021-300-500

    450

    20
    24

    14
    18

    R-020-450-500
    R-024-450-500

    600

    25
    33

    19
    29

    R-025-600-500
    R-033-600-500

    900

    30
    53

    25
    48

    R-030-900-500
    R-053-900-500

    2000

    50
    80

    45
    75

    R-050-2000-500
    R-080-2000-500


  • Ordering information +


    Note:CompatibleAlphaKit of detectors:ENS-Series(Installation and testing included with purchase of new system)、ENS8Series(new system8Package spare parts)、BInterfaceULTRA-ASand low backgroundR seriesDetector model warranty andAlphaKit products(DUO、MEGA、ARIA、ENSEMBLE)Compatible. All other detectors require special approval to ensure compatibility and specifications.

    *The first three digits of the model number indicate when using standard ORTEC electronics and a 0.5-μs shaping time constant.241Am, total system resolution FWHM of 5.486-MeV α. The beta resolution is approximated by the pulse generatorWidthFWHM。




    Effective area
    (mm2)
    Minimum resolution thickness 100 µm Minimum resolution thickness 100 µm 
    Model No.  Model No.
    300 TR-SNA-300-100 BR-SNA-300-100 
    450 TR-SNA-450-100 BR-SNA-450-100 
    600 TR-SNA-600-100  BR-SNA-600-100
     900  N/A  BR-SNA-900-100

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.