KARRAY / PRODUCT DETAILS

Trans-SPEC-N battery powered portable HPGe gamma spectrometer

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Trans-SPEC-N battery powered portable HPGe gamma spectrometer image

Trans-SPEC-N battery powered portable HPGe gamma spectrometer

Product model:

Brief description:High-purity germanium gamma spectroscopy measurements with a portable in-situ isotope spectroscopic system with neutron detector

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

trans-SPEC-N Battery Powered, Portable HPGe Gamma SpectrometerHigh-purity germanium gamma spectroscopy measurements using a portable in-situ isotope spectroscopic system with a neutron detector.

Trans-SPEC-N is an N-type HPGe gamma-ray spectrometer that is easy to operate and can meet almost any need. It doesn't require liquid nitrogen or long cables. It integrates almost all functions and is ready to use.
  • No Liquid Nitrogen Requirement - Miniature, high-reliability, "runable" Stirling cycle refrigerator requires no liquid nitrogen; detector element is encapsulated in a high-reliability, low-loss, all-metal sealed cryostat.
  • Neutron Damage Resistant - N-Type HPGe Detector.
  • Large Energy Range - 40 keV to 11 MeV energy range for higher energy prompt gamma during neutron interactions.
  • High sensitivity - large volume (>50% relative efficiency) HPGe detector.
  • High Stability - Digital electronics provide solutions for difficult analyzes under harsh conditions.
  • Bright and clear - VGA resolution display and touch-sensitive operation screen.
  • All-in-one integrated design - rugged and compact, no interconnections required - easy to install and use.
  • Smart - nuclide identification and activity calculation for nine regions of interest (ROI).
  • Reliable connectivity - USB 2.0 and wireless 802.11 communications, built-in GPS and Secure Digital Input/Output (SDIO) spectrum storage.
  • Flexible - Works with a variety of power sources, including internal battery, auxiliary external battery, car battery (any 12 V DC), and line power; switches automatically.
  • information +

    • Download link trans-SPEC-N Brochure
    • Download link trans-SPEC-N brochure (A4)
    • Download link trans-SPEC-DX-100T/trans-SPEC-N manual
  • More information +


    trans-SPEC-N is an N-type HPGe gamma-ray spectrometer that is easy to operate and meets almost all needs. It doesn't require liquid nitrogen or long cables. It integrates almost all functions and is ready to use.

    Many ORTEC trans-SPEC and Detective instruments deployed in the field have proven the reliability of this basic design and the revolutionary micro-Stirling cooler, which provides reliable and efficient cooling of integrated HPGe detectors.

    HPGe detector and cooler
    The trans-SPEC-N HPGe detector uses ORTEC GMX series N-type crystal with a diameter of 67 mm and a length of 69 mm, with a relative efficiency >50%.

    Large HPGe crystal improves sensitivity and reduces MDA time. The "supersquare" geometry means high efficiency at energies above 2 MeV.

    The crystal is housed in an all-metal sealed ruggedized cryostat and cooled by a highly reliable miniature Stirling cycle refrigerator. The refrigerator can provide approximately 1 W of cooling capacity at 100°K and consumes no more than 25 W of power during operation.

    digital electronic equipment
    Detector signal processing is implemented by advanced digital electronic equipment. The active digital noise reduction filter (LFR) in the digital spectrometer reduces the impact of mechanically generated microphonic noise on the detector output signal, resulting in good energy resolution. Under password control, the user interface controls the parameter settings of the electronic device.

    display and control
    The trans-SPEC-N model features a bright and clear VGA resolution display and a touch-sensitive operating screen. Menu navigation is very intuitive. In logarithmic and linear display modes, real-time radionuclide gamma-ray spectra can be displayed and manipulated (e.g., vertical scale, zoom) similar to conventional multichannel analyzers.

    There are three rows of buttons logically grouped together. The top row is for ROI operation and navigation, the second row is for spectrum display control, and the bottom row is for hardware control, storing spectrum data, and navigating to menu mode.

    Real-time activity calculation...no PC required!
    trans-SPEC-N can use internally stored calibration information to perform simple nuclide activity calculations at the push of a button without the need for a PC. Easily manage: nuclide libraries for analysis, display of peak labels, unit labels and calibration parameters.

    These parameters can be easily created and downloaded to trans-SPEC-N by MAESTRO (MCA simulation software), or entered directly. Parameters can be changed in the field to adapt to changing needs. Activities can be calculated for lists of up to 9 nuclides. Spectral data can be saved and then reanalyzed in more detail with more sophisticated computer analysis packages such as GammaVision.

    Peak information function
    The Peak Information feature allows users to easily check if everything is OK with their data.

    Data security
    MCA data security is an important consideration. Menus are digitally password or PIN protected. Actions can be divided into two categories: users and administrators. The user password protects the instrument from unauthorized use and allows the user to protect data stored in memory. ADMIN or Setup functions are protected by different administrator passwords. ADMIN functions can only be changed by administrators to ensure results are based on the correct parameters.

    Setup controls
    All relevant instrument settings can be controlled under password protection.

    Instrument "health status"
    The trans-SPEC-N HPGe detector uses "SMART-1™" diagnostic technology to verify the normal operation of the instrument. "Health status" and instrument status are clear at a glance.

    CONNECTIONS programs (such as MAESTRO included with the trans-SPEC-N) can read the health status parameters and display them on the laptop (if connected) or on the status screen of the trans-SPEC-N. A user-developed software package can read the status register via trans-SPEC-N for spectrum QA.

    Flexibility in power supply selection
    trans-SPEC-N can be powered by a variety of power sources. For initial cooling from ambient temperatures, it can be placed on a docking station or connected to a compact AC/power adapter/charger (PAC). The docking station has small air flow aids to assist with initial cooling in high ambient temperatures (>40°C).

    MCA Simulation and Spectral Analysis... Comes with MAESTRO MCA Simulator
    Comes with version of MAESTRO MCA software to run on your PC or laptop. It provides a standard graphical user interface to control all system parameters from a convenient large screen.

    MAESTRO is an ORTEC CONNECTIONS series product that can form a complete system network with other ORTEC spectrometers and supporting computers. MAESTRO includes functions such as identifying peaks, editing libraries, creating, printing and saving regions of interest (ROIs), performing energy calibrations and automating tasks using simple "job flows".

    Create your own custom software with the optional A11 toolkit
    The optional A11 CONNECTIONS Programmer's Toolkit is also available for those users wishing to integrate trans-SPEC-N into their own software systems. The toolkit provides ActiveX controls to simplify programming in LabVIEW, Visual C++, and Visual Basic. For more information about the toolkit, please contact us to request the A11 Programmer's Toolkit manual.

  • Specifications +


    Internal high-purity germanium detector
    Crystal size Typical Diameter 67 mm x Length 69 mm. Coaxial. Type N high purity germanium.
    relative efficiency >50% typical (ANSI/IEEE 325-1996).
    resolution ≤1600 eV @ 122 keV ; ≤2.5 keV @ 1332 keV .

    peak shape

    1.9Typical value (FWTM/FWHM)

    Cold fingers and refrigeration

    "Ultra-high vacuum" cold finger, Stirling refrigerator with high reliability and low power consumption. Cold finger design allows users to close and reopen at any timetrans-SPEC-N, rather than the traditionalHPGeThe detector will then need to wait for a complete rewarming cycle (warm up before cooling down). This feature is extremely useful during measurement activitiesThe earth improvesSystem availability. 

    digital noise suppression

    LFRfilter


    Digital MCA and Data Processor

    show

    VGA 640 x 480 TFT, readable in sunlight, sensitive to touch, and can be operated with fingers or stylus.

    data processor

    Marvel 806 MHz XScale。

    data storage

    internalRAMand removableSDcard.

    computer interface

    connected to laptopUSBinterface. PassMicrosoft®ActiveSyncperform spectral transmission. PassMicrosoft“remotedsp.exe” (included) for remote control.Wi-Fi(802.11) Communication software is optional.

    GPS(Positioning system)

    conform to internalNMEAstandardWAAS。

    numbersMCA

    with internal storage of spectral data.

    digital noise suppression

    “LFRfilter"ORTEC(Application pending).

    conversion gain

    16kchannel.

    Number of stored spectra

    No limits on mobile storage.

    Full screen display and zoom mode

    Show multipleROI。

    Main display configurable status line

    The user-configurable parameter display allows selection of two parameters from the following: Cursor Energy, Position, Time Alive, Time Alive Remaining, Real Time Remaining, Battery Remaining, Count Rate,ROICount rates and counts.

    energy calibration

    Quadratic fit of energy to channel.

    Online activity calculation

    Can be up to9Perform online activity calculations and uncertainty calculations over a user-defined area and display them on the screen. Activity is obtained by dividing the net count rate by a user-supplied efficiency factor.

    Multiple presets

    Live time, real time, peak integrated count, peak count, uncertainty and multinuclidesMDA. Can specify up to20nuclideROI. when all are satisfiedMDACollection will stop when requested. real time/living time for1Multiples of seconds.


    System hardware settings

    Coarse gain adjustment

    1、2、4、8、16or32

    Fine-tune gain

    0.45Arrive1

    Using the available gain setting range, the following can be achieved~40 keVto~11 MeVfull energy range.

    conversion gain

    trans-SPEC-NThe conversion gain can be controlled by software at512Arrive16kcontrol between channels.

    Dead time correction

    According toGedcke-HaleMethod for extended live time correction. Accuracy: Reference area peak value per second0Arrive50,000Variation between counts ±3%。

    Linear

    Integral nonlinearity: measured with a mixed source, at the front of the spectrum99.5%<±0.025%。
    Differential nonlinearity:<±1%。
    Digital Spectral Stabilizer: Stabilizes gain and gain via computer control.

    temperature coefficient

    Gain:<35 ppm/°C。[Usually30 ppm/°C。]
    Offset:<3 ppm/°C。

    Overload recovery

    During gain, at2.5pulse width without overload fromX1000Overload returns to rated output2Within %. (UseMAESTRO InSightOscilloscope measurements. )

    Pulse accumulation discard

    Automatically set thresholds. Pulse pair resolution is typically500 ns。

    Digital gated baseline restorer

    Computer controlled recovery rate adjustment (high, low and automatic).
    U.S.S.5,912,825。

    LLD

    Set a digital low level discriminator in the channel.LLDSets the following hard truncation of data in the channel.

    ULD

    Set a digital high level discriminator in the channel.ULDSet up hard truncation of data in the channel above.

    counting rate meter

    MCAand/orPCThe count rate is displayed on the screen.


    Physical specifications

    Overall size

    (includes handle,GeDetector end caps and shock absorbers)
    39.4cm long x 16.3cm wide x 34.9cm high (15.5inches long x 6.55inches wide x 13.75inches high)

    weight

    24.4pounds (11.1kilogram)

    Internal battery life

    When the internal battery is fully charged, the cooled detector25°CCan run continuously under>3hours; battery life can be extended indefinitely by using an external battery pack in the form of a "battery strap". The unit will continue to operate once it cools down.

    Input power

    10-17 V DC 30 WOr a battery charger powered by automatic induction power.

    Operating temperature range/Humidity

    -10to+40°C,35°Crelative humidity<90%, no condensation.

    Communication port

    External interface to the system

    • 1aSD(Secure Digital) card slot (3.3 V)。
    • 1for "ActiveSync” function or for external computers orMCAOperation (includedActiveSyncand remote display software)USBinterface.
    • WiFi 802.11Communication software optional.
    • 1audio headphone jack.

    Cooling time

    High reliability chillers are designed for continuous operation. Between measurements, the instrument is powered by DC power, a car battery, or other high-capacity device. The initial cooling time depends on the ambient temperature, but25°CUsually<12hours.

  • Accessories +


    Detective trans-SPEC Hard Side CasePelicanShipping box. Rugged, waterproof wheeled transport case.

    Model Description
    DetectiveEX-OPT-2

    DetectiveEX-OPT-3
    Provide equipmentSpace with docking station

    Space case for AC/DC power adapter/charger (PAC-II)

    DETECTIVE-OPT-8 Detective Shoulder StrapShoulder straps. Attached to the instrument for easy portability. The instrument comes with a strap.

    Model Description
    TSP-OPT-8 Shoulder strap

    DETECTIVE-OPT-13 Detective AC/DC Power Adapter/Charger PAC-IIAC / DCpower adapter/charger (PAC-II). Compact docking station designed for conveniencemoveAnd design.anytimeCharge the instrument battery and keep it ready. Charge it to maintain constant availability. Single cable output to instrument. Use a separate cable for input from the car or mains power supply. The charging circuit is internal. Does not include a user-supplied calibration check source if necessary, and does not provide forced air cooling to assist with initial cooling at high ambient temperatures. This will not affect use at high ambient temperatures, but may affect the initial cool down time of the instrument. oneAC / DCpower adapter/Charger comes with-PACProvided together with the instrument model. Size9.88&rdquo; L x 7.48&rdquo; W x 2.84&rdquo; H, heavy3.55lbs.

    • The battery charges 40% faster than previous models.
    • Charge your battery more fully; extend battery life by 30%.
    • Auto-sensing power input AC/DC, no need to switch
    • Resolution does not decrease during charging.
    • The front panel eliminates the charging on/off switch.
    Model Description
    TSP-OPT-12 AC/DC power adapter/charger

    M-1-T2 Tripod for DetectiveM-1-T2 tripod.

    Model Description
    M-1-T2-100-VERT Variable length tripod and mounting hardware.

    DETECTIVE-OPT-15 Ultra Battery Extender with ChargerSuper battery extender with charger. Powers the instrument, thereby maintaining the current state of charge of the internal battery. Does not charge the built-in battery. Battery life >8 hours. Supports hot swapping. Weight ~3 lbs.

    Model Description
    TSP-OPT-15 Super battery extender.

    DETECTIVE-OPT-16 Detective Docking StationDock II. Includes calibration check source and AC power source. The cooling fan helps in cooling from the ambient temperature. The charging circuit is inside the docking station. The docking station charges and keeps instrument batteries ready, charged and calibrated for immediate use. Single cable output to instrument. Enter vehicle or mains power from a separate cable assembly. The instrument comes with a docking station.

    Calibration Check Source Description: The calibration check source is located inside the docking station. It includes a solid sealed ~0.25uCi (9250-Bq) Cs137, located on the front of the dock. This radioactive source can only be sold in pre-assembled form and not separately. Users are strongly advised not to remove radioactive sources. ORTEC does not assume any responsibility or consequences for this action. If the radioactive source is not needed for some reason. Please specify when ordering.
    • The battery charges 40% faster than previous models.
    • Charge your battery more fully; extend battery life by 30%.

    Model  Description
    TSP-OPT-16 dockstand 

    Detective CollimatorOptional collimator

    Model Description
    TSP-100-COL-ST Steel collimator, 4 mm thick
    TSP-100-COL-W Tungsten collimator, 4 mm thick
  • Ordering information +


    Model

    Description

    TRANS-SPEC-N

    Trans-SPEC-NPortable spectrometer with universal mains power supply andMAESTROsoftware.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.