Lead-embedded meter ruler (lead ruler) KR018
View product
Product model: Brief description: Product introduction Lead-embedded scale meter ruler (lead ruler) KR018 is 30cm long, 3cm wide, 1mm scale spacing, and has lead-embedded scales.
Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management
806 products

View product
Product model: Brief description: Product introduction Lead-embedded scale meter ruler (lead ruler) KR018 is 30cm long, 3cm wide, 1mm scale spacing, and has lead-embedded scales.

View product
Product model: Brief description: Filter plate set (copper plate, aluminum plate, lead plate) KR012-KR01 70.5mm thick copper plate 20cm x 20cm - KR012 1.5mm thick copper plate 20cm x 20cm - KR013

View product
Product model: Brief description: Used to detect the consistency between the light field and the irradiation field of the X-ray machine. This phantom is also used to detect the positioning of the center of the movable grid (Bucky) clamp.

View product
Product model: Brief description: Patient body thick phantom Serial number: VD0203200 25mm thick aluminum with external support plate, used with Primus I-L or DIGI-13 phantom for testing.

View product
Product model: Brief description: Primus I-L detection phantom Serial number: VD0203525 According to DIN 6868-4, 2007 standard, it is used for stability detection of digital fluoroscopy (dynamic flat panel) or conventional fluoroscopy (image intensifier TV) X-ray system.

View product
Product model: Brief description: Primus I-S detection phantom serial number: VD0203515 According to DIN 6868-4, 2007 standard, it is used for stability testing of digital fluoroscopy (dynamic flat panel) or conventional fluoroscopy (image intensifier TV) X-ray system.

View product
Product model: Brief description: Meet the "WS76-2020 Quality Control and Testing Specifications for Conventional Medical X-ray Diagnostic Equipment" Digital X-ray photography and fluoroscopy system detection phantom detectable parameters: Spatial (line pair) resolution Low contrast resolution High contrast resolution Boundaries of useful wire harnesses

View product
Product model: Brief description: The low-contrast detail detection phantom is used to quickly and quantitatively detect image imaging quality, and can be used in X-ray radiography systems, CR systems (TO16); 2. Diameter 250mm, thickness 10mm; there are 12 groups of different detail points in the circular plate, and each group has 12 detail points of different diameters. The contrast of 144 detail points ranges from 0.0014 to 0.924 (at 75kV and 1.5mm copper filtering).

View product
Product model: Brief description: Low-contrast detail detection phantom Leeds, UK / TO16 / TO201. The low-contrast detail phantom is used to quickly and quantitatively detect image imaging quality, and can be used in X-ray radiography systems, CR systems (TO16); fluoroscopy and angiography systems (TO20). 2. Diameter 250mm, thickness 10mm; there are 12 groups of different detail points in the circular plate, and each group has 12 detail points of different diameters. The contrast of 144 detail points ranges from 0.0014 to 0.924 (at 75kV and 1.5mm copper filtering).

View product
Product model: Brief description: Low contrast-detail phantom CD DISC2.0 includes analysis software and carrying case Serial number: VD0203720 It is a contrast-detail phantom dedicated for quality control of fluoroscopy systems, providing quantifiable contrast detail information to clinical practice. Medical diagnosis does not only rely on the image itself, but the diagnostician's ability to perceive image details is also crucial.

View product
Product model: Brief description: The German IBA CR/DR detection phantom DIGI-13 is used for quality inspection of CR and DR imaging systems (including uniformity, spatial resolution, low contrast resolution, visible light field and X-ray field calibration and artifacts, etc.) according to DIN6868-13 standard.

View product
Product model: Brief description: Used for quality inspection of all types of CR and DR imaging systems. The following parameters can be detected simultaneously: spatial resolution, low contrast resolution, dynamic range, light field and illumination field consistency, and spatial distance accuracy.

View product
Product model: Brief description: Multifunctional image quality detection phantom is used for CRDR low-density resolution, spatial resolution, radiation field and light field consistency, and uniformity detection.

View product
Product model: Brief description: According to DIN 6868-13 standard, used for quality inspection of CR and DR imaging systems (including uniformity, spatial resolution, low contrast resolution, calibration and artifacts of visible light fields and X-ray fields, etc.).

View product
Product model: Brief description: Used for filming, digital X-ray imaging systems and fluoroscopy system inspections. It can detect items such as light field/radiation field consistency, spatial resolution, low contrast resolution, dynamic range and image consistency.

View product
Product model: Brief description: Used for filming, digital X-ray imaging systems and fluoroscopy system inspections. It can detect items such as light field/radiation field consistency, spatial resolution, low contrast resolution, dynamic range and image consistency.

View product
Product model: Brief description: The NY-405RF low-contrast detail detection phantom can redefine the details and contrast observed by radiologists. It can be used throughout the entire range of radiological diagnostic imaging systems, such as fluoroscopy and angiography. It has 225 holes that create subtle contrast changes.

View product
Product model: Brief description: DRLRIEC-18 low contrast detail inspection phantom • DRLRIEC-18 meets WS 521-2017 "Specification for quality control inspection using digital radiography (DR) systems" Appendix B.1 IEC low contrast phantom requirements • 40mm organic glass (PMMA) module

View product
Product model: Brief description: Low contrast phantom. This phantom consists of a set of aluminum circular disks with a diameter of 1cm (21 circular holes in total). If used, block attenuation phantoms provide X-ray attenuation and hardening under automatic exposure control, allowing these disks to produce X-ray radiation contrast varying from 0.8% to 20%.

View product
Product model: Brief description: Low contrast test card, the test card is made of 20mm thick aluminum plate. Lcm aperture round holes are evenly distributed on the aluminum plate. The depth of the holes (mm) and contrast (value in brackets 96) vary from 0.07mm (03596) to 32mm (16%), a total of 19 round holes.