KARRAY / PRODUCT DETAILS

German IBA company DOSE1 radiotherapy dosimeter

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

German IBA company DOSE1 radiotherapy dosimeter image

German IBA company DOSE1 radiotherapy dosimeter

Product model:

Brief description:DOSE1 is a portable, single-channel, high-precision reference-level electrometer. Its measurement indicators significantly exceed the standards specified by IEC 60731 and AAPM. It has extremely high accuracy and provides extremely high resolution capabilities over a wide dynamic range. This electrometer can use ionization chambers, semiconductor probes and diamond probes to measure absorbed dose. The use of radioactive inspection sources can verify the stability of the ionization chamber response and perform cross-calibration.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

germanyIBA DOSE1 radiotherapy dosimeter

DOSE1 is a portable, single-channel, high-precision reference-level electrometer. Its measurement indicators significantly exceed the standards specified by IEC 60731 and AAPM. It has extremely high accuracy and provides extremely high resolution capabilities over a wide dynamic range. This electrometer can use ionization chambers, semiconductor probes and diamond probes to measure absorbed dose. The use of radioactive inspection sources can verify the stability of the ionization chamber response and perform cross-calibration.

Technical parameters

DOSE 1

polarization voltage

Detector Connector Type

-Standard type

-Backup type (convertible type) temperature range:

relative humidity:

Host power input: computer interface:

Appearance size:

weight:

Measurement mode/range

charge(dose) current(dose rate)

Measure physical quantities/unit

Electrical:

Compound amount:

rate time unit: Interval time range: Accuracy/Repeatability: Leakage current:

500v, The design interval is1V

three axisTNC(Screw type)and three-axisBNC(bayonet type) Mtype,BNC/Bananaand three-axisTNC,three axisBNC 15~35°C

10~80%, maximum: 20g/m3

100~240V, 50/60Hz

Two-wayRS-232,Management and measurement software259mm(L)x259mm(W)x165mm(H) 3.5Kilogram

40pC~1.0C resolution0.1pC

40pA~1000nA resolution0.1pA

charge(C),current(A)

Gy, Sv, R, rad, remi

seconds, points,hours

1~9999seconds

0.2%

10fA, Typical value1 fA

linearity: Stability:

full range

every year

0.25%

0.25%

show:

zero drift: storage:

background deduction:

graphicLCDmonitor,160Degree of viewing angle

automatic, 60within seconds

All setup parameters and detector parameters are stored inEEPROMOpening of middle band memory/off mode

computer operating system:

Windows XP Professional Windows 2000

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.