Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

German QUART dido2100K type X-ray diagnostic meter image

German QUART dido2100K type X-ray diagnostic meter

Product model:

Brief description:German QUART company's dido2100K X-ray diagnostic meter (dose/dose rate/kv/pulse/exposure time meter) covers almost all applications in the field of X-rays. Regardless of whether it is a traditional or digital procedure, dosimeters can be used in the following fields: radiographs, pulse fluoroscopy, digital subtraction DSA, dental machines, 3D (cone beam CT) and mammography.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

germanyQUART  dido2100K type X-ray diagnostic measuring instrument

germanyQUART's dido2100K X-ray diagnostic meter (dose/dose rate/kv/pulse/exposure time meter) covers almost all applications in the X-ray field. Regardless of whether it is a traditional or digital procedure, dosimeters can be used in the following fields: radiographs, pulse fluoroscopy, digital subtraction DSA, dental machines, 3D (cone beam CT) and mammography.

    germanyQUART's dido2000K type X-ray diagnostic meter (dose/dose rate/pulse/exposure time meter) does not have mammography function. The remaining technical specifications are the same as the dido2100K type X-ray diagnostic meter (dose/dose rate/kv/pulse/exposure time meter). Performance features:

•Multifunctional quality controller

•zuijia size and design

•Miniature multifunctional advanced solid state detector

•Miniature probe can be used for measurements in limited spaces

•Detector positioning is direct and easy

•Can be measured after scattered radiation

•Auto exposure control is not affected

•The wavelength range can be measured directly in dental panoramic tomography.

Reference: Mitchell and C J. Martin, Comparison of ionization chamber and semiconductor detector wavelength range measurements in dental panoramic tomograms, J. Radiol. Prot. 33 321 (2013).33 321(2013).

Technical specifications

dose range :5nGy-999Gy (dido2100K);10nGy-999Gy (dido2000k)

         Resolution:0.01 nGy

         Error:<5%

Dose rate range:0.1μGy/s-0.1Gy/s

Resolution:0.1nGy/s

Error:<5%

Dose rate mode displays three values  real time measurement time/time period/maximum dose value

kV peak Scope:21 – 36 kV / 40 – 160 kV (dido2100K)

40 – 160 kV (dido2000K)

         Resolution:0.1KV

         Error:<2% (calibrated exposure conditions)

         kV peak2 modes kVp / effective kV (PPV)

Pulse range:1-65.000

         Resolution:1 pulse

Error:±1 pulse

Exposure time  Scope:0.5ms-40s (20/25/30s optional)

         Resolution:0.1ms

Error:<5%(±0.5ms)

Exposure time mode (2 types) Exposure time/image time (IEC60601-2-54)