KARRAY / PRODUCT DETAILS

American RSD head simulation CT phantom

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

American RSD head simulation CT phantom image

American RSD head simulation CT phantom

Product model:RS-250

Brief description:American RSD phantom, model: RS-250, category: quality control phantom, brand: American RSDRSDRS-250 head CT phantom, RS-250 head simulation CT phantom detailed introduction: RS-250 head simulation CT phantom has 5 layers to test all performance of computed tomography.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

USARSD  RS-250 Head simulationCT phantom                                                       

Overview 

Model:RS-250,Category: Quality control phantom,Brand: United StatesRSD

RSDRS-250 head CT phantom, RS-250 headimitationtrueDetailed introduction to CT phantom:

RS-250 headimitationtrueCT phantomYes5 layers to testcomputed tomographyAll properties of:

Part A: A 0.4 mm thick aluminum plate is set at a 45° angle, and the beam width and slice thickness are measured.  

 RS-250A part

Part B: The dosimetry section provides patient exposure control and checks for abnormal internal doses before actual patient scanning. Custom housing TLDs with sticks or chips are available.  

 RS-250B part

Part C: Cylindrical tumors graded in size and radioactivity establish high- and low-contrast resolution and show partial beam averaging effects.   

RS-250C part

Part D: The anthropomorphic part provides actual auditory ossicles in the inner ear with air contrast and the fractured petrous bone. Small posterior fossa tumors are placed in areas that are difficult to image with most scanners.  

 RS-250D part

Part E: 1/4" diameter aluminum rod on the longitudinal axis of the mannequin to check general alignment, "dry water" gives a realistic "noise check".

Features:

personification

castAcround skull

Check important physical parameters

Provides a true system check

ideal training

Polycarbonate base sized for scanning parallel or perpendicular to longitudinal axis

SAG: RS-250, RSDRS-250, RS-250 head CT phantom, head CT phantom, RS-250CT phantom

638179275347633534537.png


Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.