WPC-1150-GFW automatic sample changer
Product model:
Brief description:3

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- When using the long pole radiation measuring instrument, the operating procedures must be strictly followed.
- Do you really know about thermoluminescent personal dosimeters?
- Application of radiotherapy three-dimensional water tank in radiotherapy
- Long pole radiation measuring instrument is an important link in the radiation protection system
- Online radiation alarm is an indispensable part of the modern radiation safety management system
- How to use the American CIRS ATL040 ultrasound phantom for ultrasound equipment calibration?
- How does the German IBA line card evaluate the resolution capability of the X-ray machine?
- Solid water phantoms are available in a variety of standard sheet thicknesses
- Online radiation alarm is the key equipment for modern radiation protection
- Surface Contamination Detector Supplier Screening Guide: Key Points to Consider from Qualifications to Services
Detailed introduction

- 3.5 in. (8.9 cm) or 5.0 in. (12.7 cm) diameter pie flow detector
- Anti-cosmic ray coincidence detector
- low background system
- Customer selectable pallet sizes
- 50 sample capacity
- touch screen interface
- Real-time monitoring of gas circuit
information +
-
α/β automatic counting system brochure
-
α/β automatic counting system brochure (A4)
-
More Information +
The WPC-1150-GFW‑3.5 and WPC-1150-GFW-5 low background automatic sample change measurement systems use air flow proportional counter detectors with diameters of 3.5 in. (8.9cm) or 5.0 in. (12.7cm) respectively. Each counter system has a built-in touch screen based controller and is primarily used in healthcare physics applications and environmental applications. They are ideal for large diameter air filter papers, targeting large volume air samples.Specifications +
Performancetypical background WPC-1150-3.5 WPC-1150-5 Alpha 0.3 cpm 0.4 cpm (0.5 cpm guaranteed) Beta 1.5 cpm 4 cpm (5 cpm guaranteed) Typical efficiency 230Th 27% 90Sr/90Y 63% 99Tc 41% 63Ni 20% crosstalk Alpha-Beta <0.1% Beta-Alpha <0.1%
Equipment parametersdetector WPC-1150-GFW-3.5: 3.5 in. (8.9 cm) diameter, pie-shaped gas flow detector
WPC-1150-GFW-5: 5 in. (12.7 cm) direct, pancake flow detectordetector window Aluminum film, 80 µg/cm2 Coincidence detector 1 Large volume flow detector
working gas P-10, 60 cc/min,10 psi
Gas-PRO P-10 Gas Monitoring System
shield 4 in. (10 cm) lead shield Sample size User selectable size, accommodates 5/16 in. (7.9 cm) platters
WPC-1150-GFW-3.5: Effective detection diameter 3.5 in. (8.9 cm)
WPC-1150-GFW-5: Effective detection diameter 5 in. (12.7 cm)Sampling mechanism 50 sample capacity autosampler, includes barcode reader, from 1-999 Counting mode Only Alpha is measured, only Beta is measured, Alpha/Beta are measured simultaneously interface touch screen Data export USB flash drive, RS-485
power supply 117 V ac, < 0.2 A, 50/60 Hz. 230 V ac, < 1.0 A, 50/60 Hz
Usage environment 10–40 °C (50–104 °F). 20%–90% non-condensing
Size 25 in W x 36 in. D (62.5 x 91.4 cm)
total amount 1800 lb (816 kg)
Ordering information +
Model Description ORT-WPC-1150-GFW-3 Automatic sample changing, low background counter with 3.5 in. (8.9 cm) diameter cake flow proportional counter ORT-WPC-1150-GFW-5 Automatic sample changing low background counter with 5 in. (12.7 cm) diameter cake flow proportional counter Optional accessories PIC-700-0007 Planchet, 2 inch x 1/8 inch, set of 100
PIC-700-0008 Planchet, 2 inch x 1/4 inch, set of 100
PIC-700-0009 Planchet, 2 inch x 5/16 inch, set of 100
ORT-Vista FC Health Physics Application Software ORT-Vista 2000 Radiochemical laboratory application software