| The front-end electronics include input field-effect transistors (FETs) and feedback elements for the charge-sensitive preamplifier. Feedback components include capacitors and resistors (passive feedback) or transistors (active feedback). Preamplifiers with active feedback, such as transistor reset preamplifiers (TRP), are used for ultra-high count rate applications. If the detector temperature begins to rise, the temperature sensing element located in the cryogenic vacuum enclosure automatically switches off the HV power supply. The front-end electronics are packaged in a cryogenically cooled enclosure to minimize electronic noise. Both the input FET and feedback elements have excellent noise characteristics at ~120 K. Image: Simplified electronic diagram of the detector and preamplifier "front end" in a cryogenically cooled germanium radiation detector. The feedback element can be a resistor or an electronic switch that resets the FET gate voltage to zero whenever a given threshold voltage is reached. | ![]() |

HPGe Radiation Detector Electronics
Product model:
Brief description:ORTEC radiation detectors feature multiple electronic design features that enhance performance and safety

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- Explosion-proof radiation measuring instrument builds a set of "early warning-positioning-assessment" chain
- KARRAY Technology: The cutting-edge power of domestic dose area product meters, technical strength and product line analysis
- Radiotherapy three-dimensional water tank is an important equipment in the field of radiotherapy
- Low contrast detail detection phantom丨Product Encyclopedia
- When using the long pole radiation measuring instrument, the operating procedures must be strictly followed.
- Application scenarios for low-contrast detail detection phantoms
- This knowledge of CT dose detection phantom is worth learning
- Quality control of imaging diagnosis and treatment: the application value of dose area product instrument
- Low-contrast detection phantom to protect health
- Nuclear radiation monitoring expert: The technical foundation and market reputation verification of KARRAY Technology’s neutron dose rate meter
Detailed introduction
Front-end electronic equipment +
preamplifier +
In addition to the front-end electronics, the sealed HV filter and charge-sensitive hybrid preamplifier circuit are located behind the radiation detector assembly in the PopTop package. They are located outside the vacuum chamber at room temperature.

The long time constant of the HV filter ensures that the voltage is gradually applied to the radiation detector. This protects the FET from voltage spikes. When cold, any of ORTEC's new HPGe radiation detectors can be switched on to full bias voltage without risk of damaging the FET.
Some additional notes about radiation detector preamplifiers: All preamplifiers are of the "charge sensitive" type, and all have cryogenically cooled "front ends" for minimal electronic noise and excellent energy resolution. Three different feedback mechanisms are used:br />
- and see "resistive feedback" (see front-end electronics). In this case, the feedback circuit contains a resistor and capacitor in parallel.
- For coaxial radiation detectors at high count rates (>75 kcps), the feedback circuit replaces the feedback resistor with a junction transistor that turns on when the input FET gate voltage exceeds a certain threshold voltage. This resets the input FET gate voltage to zero. This type of preamplifier is called a transistor reset preamplifier (TRP).
- For small radiation detectors, where the electronics have resolution below 50 keV, the feedback circuit contains an LED that uses light (non-electronic switching) to reset the voltage input to the FET gate to zero through a TRP-like mechanism. This preamplifier [pulsed optical feedback (POF) available by special order] achieves ultra-low noise performance because the feedback resistance is infinite (as opposed to resistive feedback) and the capacitance on the input FET gate is not increased by the collector-to-ground capacitance of the junction transistor (as with TRP). High feedback resistance and low capacitance are key to reducing noise performance.
The A250 Series ORTEC resistive feedback preamplifier requires only 1 watt of power. This makes the preamplifier ideal for demanding portable applications such as security. The transistor reset preamp (the "add-on" option) requires about 1.8 watts of power.
The energy rate of the preamplifier in a radiation detector.
Preamp type
Detector type
energy rate (MeV seconds-1)
Resistive feedback
GEM、GMX
GLP (25、32、36 mm)
GLP (6、10、16 mm)145,000
4,000
2,200transistor reset (-PLoptions)
GEM、GMX
1,000,000
Pulsed optical feedback (special orderPOFoptions)
GLP (6、10、16 mm)
4,000
Automatic high pressure shut-off +
An automatic HV shutdown protects the input FETs and critical radiation detector surfaces if the system warms up with bias on. ORTEC uses a thermistor on the mount rather than the radiation detector element itself to sense the onset of preheating.Cable package +
Unless otherwise specified when ordering, each ORTEC radiation detector comes with a 3-foot cable bundle with individual push-in connectors:
- Signal output 93-Ω BNC
- Timing output 93-ΩBNC
- Test input 93-ΩBNC
- High voltage input 75-Ω male connector
- Preamplifier power supply 9-pin D female connector
A matching 10-foot cable pack for each conductor is provided for connection to supporting electronic systems.
SMART-1 and SMART-INTERFACE smart detectors +
SMART-1 is an option for the GEM, GMX, GLP, SGD and Profile series of radiation detectors. This option integrates a microprocessor-controlled module with a radiation detector assembly. This module, controlled via the MCA's RS-232 link, provides HV bias to the radiation detector elements and provides status information for the following radiation detector functions:
- Preamplifier ±12, ±24 V
- Detector element temperature
- Detector high voltage on/off/set/read
- Detector overload status
- Detector is off
- Detector serial number (read only)
- Detector verification code (read/write)