Model 296 ScintiPack photomultiplier tube base with preamplifier and high voltage power supply
Product model:
Brief description:Suitable for scintillation detectors using Class 10 PMT that plugs into a standard 14-pin socket Internal adjustable high voltage bias supply

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- A thermoluminescence dosimeter is an analytical device used to measure radiation dose
- Do you know how to use nuclear radiation detectors?
- Thermoluminescent dose readers require regular calibration and calibration
- How effective is the spatial resolution test card in practical applications?
- Thermoluminescent personal dosimeters can be used in areas such as environmental dose monitoring
- Online radiation alarm is the key equipment for modern radiation protection
- Precautions when using dental phantoms
- Low contrast detail detection phantom丨Product Encyclopedia
- Thermoluminescent dose tablets are a proven dose measurement tool
- Thermoluminescence dosimeter: an important tool for accurate radiation dose measurement
Detailed introduction

- Suitable for scintillation detectors using Class 10 PMT that plugs into a standard 14-pin socket
- Internal adjustable high voltage bias supply eliminates the need for high voltage cables
- Built-in spectral preamplifier prevents box from floating
- Active biasing minimizes peak shift at high count rates
- Anode timing output for compliance measurements
- Low power consumption (240 mW) for portable applications
- Convenient single cable connection suitable for most applications
The ScintiPack photomultiplier tube base (Type 296) offers everything you need in a scintillation detector in a compact package: low power, adjustable, high voltage power supply, active bias and spectral preamplifier. Incorporating the bias supply into the photomultiplier tube base eliminates the need for high-voltage cables to connect to a bulky external high-voltage power supply. ScintiPack operates with extremely low power consumption (240 mW). This makes the ScintiPack ideal for portable applications as well as high-density detector arrays.