KARRAY / PRODUCT DETAILS

Light field detection board

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Light field detection board image

Light field detection board

Product model:

Brief description:The light field irradiation field detection board (light field irradiation field consistency detection board) is a tool used to detect the irradiation field consistency of radiation sources such as X-rays or gamma rays.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

The light field irradiation field detection board (light field irradiation field consistency detection board) is a tool used to detect the irradiation field consistency of radiation sources such as X-rays or gamma rays. It usually consists of a plate of lead or other high-density material of a specific shape and size that is placed between the radiation source and the object to be measured to simulate actual exposure conditions.

By using a light field detection plate, it is possible to measure and evaluate whether the radiation source's field size, shape and position are consistent and whether there are any deviations or errors. This is very important to ensure the accuracy and safety of radiation therapy, because if the radiation source field is inconsistent, it may cause excessive or insufficient radiation dose to some tissues, thereby increasing the risk to the patient.



Light field detection panels often require use with specific software for data analysis and results evaluation. These software can help doctors and technicians determine whether the location or parameters of the radiation source need to be adjusted to achieve better exposure.

The steps to use the light field detection board are as follows:

1. Prepare the detection plate: Select the appropriate light field detection plate as needed, and ensure that its surface is clean and flat.

2. Place the detection board: Place the detection board between the object to be measured and the radiation source to simulate actual exposure conditions. Make sure the position and orientation of the detection plate matches that of the object to be measured.

3. Measure: Use a radiation measuring instrument to measure the detection board and record the radiation dose or energy value. Repeat the measurement multiple times for more accurate results.

4. Analyze data: Import the measured data into the corresponding software for analysis. Software helps doctors and technicians determine whether the radiation source's field size, shape and position are consistent and whether there are any deviations or errors.

5. Adjust parameters: According to the analysis results, if it is found that the irradiation field of the radiation source is inconsistent, the position or parameters of the radiation source can be adjusted to achieve better irradiation effects. This may require re-measurement and analysis until satisfactory results are achieved.

It should be noted that the method of using the light field detection board may vary depending on different equipment and software. Before use, you should carefully read the relevant operating manual and safety guide and receive professional training.

The advantages of the light field detection board are mainly reflected in the following aspects:

1. Accuracy: The light field detection board can accurately measure and evaluate whether the size, shape and position of the radiation source are consistent, and whether there are any deviations or errors. This is important to ensure the accuracy and safety of radiation therapy.

2. Real-time: This detection tool is very easy to use and can detect the consistency of the irradiation field and indicator light field of the film camera, breast machine and indicator light field in real time, providing accurate and instant results.

3. Efficiency: By using the light field detection board, doctors and technicians can quickly determine whether the position or parameters of the radiation source need to be adjusted to achieve better irradiation effects.

4. Versatility: In addition to being used to verify that the light field is correctly aligned with the X-ray field and to verify whether the beam center is perpendicular to the image receptor plane, the light field detection board can also be used to detect the geometric characteristics of the X-ray machine, such as beam verticality deviation, deviation of the light field from the center of the irradiation field, etc.

5. Safety: The use of light field detection boards can help reduce the risks that patients may suffer due to inconsistent radiation doses, thus improving the safety of radiotherapy.
 