KARRAY / PRODUCT DETAILS

EASY-MCA 2k or 8k channel multi-channel analyzer

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

EASY-MCA 2k or 8k channel multi-channel analyzer image

EASY-MCA 2k or 8k channel multi-channel analyzer

Product model:

Brief description:Compact stand-alone MCA Two versions available with 2k or 8k resolution Fast (includes dead-time corrected logic inputs (BUSY and PUR) Gate signal input support With easy-to-use and feature-rich MAESTRO software Fast and convenient USB2 connectivity Advanced analysis software option EASY-MCA connects to PC via USB2 cable

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

EASY-MCA 2k or 8k Channel Multichannel Analyzer
  • Compact freestanding MCA
  • Two versions available, with resolutions of 2k or 8k
  • Fast (<2 μs) conversion time
  • Includes dead time correction logic inputs (BUSY and PUR)
  • Gate signal input support
  • MAESTRO software with ease of use and functionality*
  • Fast and convenient USB2 connection
  • Advanced analysis software options
EASY-MCA connects to the PC via USB2 cable. This compact MCA is stackable and portable, requiring no PC slot. Each EASY-MCA has memory capable of storing the complete energy spectrum. You can select a 2k channel, then switch from it to a 1k or 0.5k channel or an 8k channel, and finally switch to a 4k, 2k, 1k or 0.5k channel.
  • information +

    • Download link EASY-MCA brochure
    • Download link EASY-MCA brochure (A4)
    • Download link EASY-MCA Manual
  • More information +


    EASY-MCA will accept input from the amplifier for pulse height analysis (PHA). In addition to input signals, EASY-MCA also accepts ADC gate signal input, stacking reject input (PUR) and busy signal input used by the live time correction circuit. A single computer, subject to USB-2.0 data transfer speeds, can control multiple devices using USB ports or powered USB hubs.
  • Specifications +


    Performance

    ADC

    ADCIncludes sliding scale linearization and<2 μsDead time (including memory transfers).

    integral nonlinearity

    before the dynamic range99Within %, ≤±0.025%。

    differential nonlinearity

    before the dynamic range99%,<±1%。

    Gain stability

    ≤±50 ppm/°C。

    Dead time correction

    According toGedcke-HaleMethod for extended live time correction.

    USBinterface

    USB 2.0ArrivePCData transfer speeds up to480 Mbps。











    input and output

    Input

    Accepts unipolar positive signals, positive gated integrators, or0to+10 VBipolar analog pulses that are predominantly positive within the dynamic range;+12 V;0.25Arrive30 μsThe semi-Gaussian time constant of3Arrive30 μsthe time constant of the gated integrator shape, or the delay line shape, where the width>0.25 μs。Zin =1kΩ, DC coupled. No internal delays,BNCconnector.

    ADCdoor

    OptionalTTLInput with computer-selectable coincidence mode, anti-match mode, or off. The signal must occur before and exceed the pulse peak0.5-μs;Zin =1kΩ。BNCconnector.

    PUR

    Stack rejection input; acceptTTLSignal; the signal must occur before peak detection.Zin= 1kΩ。BNCconnector.

    busy

    Busy signal input used by the live time correction circuit. acceptTTLSignal; the signal must occur before peak detection.Zin= 1kΩ。BNCconnector.

    power supply

    Right12 V, power capacity up to8 W。EASY-MCAComes with power supply and cable.














    indicator light

    ADC

    instructionsADCstatus




    Software control

    (With accompanyingMAESTROused together - For more information, seeMAESTRODatasheet. )

    ADC LLD

    The computer can be accessed from0Arrive100% of full scale for control.

    ADC ULD

    The computer can be accessed from0Arrive100% of full scale for control.

    Default

    real time/living time

    20Multiple of milliseconds.

    area of interest

    Peak count/Points counting.

    Data overflow

    When any channel exceeds231-1Data collection will be terminated.

    peak uncertainty

    Acquisition stops when the statistical or counting uncertainty of the user-selected net peak reaches a specified value.

    nuclideMDA

    When the user specifiesMCAMinimum detectable activity (MDA) value reaches the specified value, data collection will stop.

    live time correction

    Gedcke-Halemethod.

    gate input

    Conform, anti-conform, close.















    electrical and mechanical

    Required power supply

    Via the power cable and the DC power supply (mains voltage110-230 V/50-60 Hz) provided0.4Ampere+12 Vvoltage.

    weight

    Net weight:0.6Kilogram (1.3pounds)Shipping weight:2.3Kilogram (5pounds)

    Size

    34.9mm(1.38inches) high x 134mm(5.25inches) wide x 205mm(8.1inches) deep [include28.6mm(1.13inches)BNCconnector]

    operating environment

    0to50°C, relative humidity0to80%, no condensation.













  • Ordering information +


    Model

    Description

    EASY-MCA-2K

    compactstand-alone2kchannelMCA. includeMAESTRO、10feetUSBinterface cable,6ft. power cord and mains power.

    EASY-MCA-8K

    compactstand-alone8kchannelMCA. includeMAESTRO、10feetUSBinterface cable,6ft. power cord and mains power

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.