KARRAY / PRODUCT DETAILS

GLP Series Planar HPGe Low Energy Radiation Detector

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

GLP Series Planar HPGe Low Energy Radiation Detector image

GLP Series Planar HPGe Low Energy Radiation Detector

Product model:

Brief description:Excellent energy resolution in the 3 to 300keV range Active area ranging from 30 to 1000mm2 Flexibility of PopTop’s timing performance Detectors larger than 36mm in diameter available Can be equipped with special feedback resistors

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

HPGe Radiation Detector Energy Range - GLP Radiation Detector
  • Excellent energy resolution in the 3 to 300 keV range
  • Effective area varies from 30 to 1000 mm2
  • PopTop Flexibility
  • timing performance
  • Detectors larger than 36 mm in diameter are available
  • Can be equipped with special feedback resistors for high speed applications
  • POF preamplifier option for excellent energy resolution and high count rates at low energies
The ORTEC GLP Series Planar Low Energy Spectrometer (LEPS) is a small area, high purity germanium spectrometer suitable for applications in the 3 to 300 keV energy range. br />
LEPS are available in diameters ranging from 6 to 36 mm, providing excellent energy resolution for low and medium energies. At low energies in nuclear structure physics, GLP detectors are distinguished by their excellent timing performance.
  • information +

    • Download link GLP Configuration Guide
    • Download link GLP Configuration Guide (A4)
    • Download link Semiconductor Detector Overview
    • Download link A review of the physics of semiconductor detectors
  • Optional accessories +


    SMART-1 option (-SMN)
    The SMART-1 option is used to monitor and report on important system functions, as well as save verification codes and report them later. It includes high voltage, so all instruments require no external high voltage power supply. The SMART-1 features a rugged ABS molded plastic housing with molded strain-relief sealed cables securely attached to the detector end cap. This prevents the detector from being seriously damaged by water leaking into the high voltage connector. The SMART-1 can be placed anywhere convenient for use without interfering with shielding or other mounting hardware.

  • Ordering information +


    SeeGLPseries planeHPGeLow Energy Radiation Detector Configuration GuideConfigure the detector.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7