ORTEC 994 Dual Counter and Timer
  • Two 8-bit decimal counters and a timer, flexible configuration to meet various measurement needs
  • RS-232-C option provides CCNIM functionality for computer control and data reading
  • Can directly drive printers with RS-232-C ports
  • An 8-digit decimal LED display can instantly read the entire counter capacity even in a dark room
  • All common controls on the front panel are easily accessible
  • 100 MHz count rate capability
  • Preset times or counts can be set with two-digit and decimal precision
  • All options are field installable

The ORTEC Model 994 dual counter and timer contains two eight-digit decade counters and a blind preset timer. The instrument has considerable functional flexibility and can complete a variety of measurement tasks. Typically, it can be used as two counters to record separate events under the control of a preset blind timer.
  • information +

    • Download link 994 brochure
    • Download link 994 Brochure (A4)
    • Download link 994 Manual
  • More information +


    When continuous reading of time is required, counter A can be called to count time while counter B records external events. This provides counter and display preset timer functionality. In some applications, it is necessary to measure the time required to count a preset number of events. For such applications, Counter A combined with a preset blind counter can be used as a preset counter, while Counter B records time at 0.01 second intervals. In measurements that require correction for dead time of the detector and its associated electronics, the Gate A input can be switched to gate the clock on and off with a time resolution of 100 ns. A positive logic signal that defines the system live time is connected to the gate A input. This configuration provides a live time clock (Counter A) and a counter (B).

    The MN X 10P option provides maximum flexibility in setting presets. The M and N values ​​provide two-digit precision, while P has the option of decimal. Preset values ​​can be selected from 0.01 to 990,000 seconds, 0.01 to 990,000 minutes, or 1 to 99,000,000 counts.

    The basic model 994 includes an 8-digit decimal LED display that allows the entire contents of counter A or B to be read out instantly, even in a dimly lit room. Readout and control capabilities can be expanded by adding field-installable options.

    The full functionality of CCNIM (Computer Controlled NIM) can be obtained by adding the RS-232-C option. This plug-in board allows computer control of all functions normally selectable from the front panel, including starting and stopping counting, readings, resets, setting presets, selecting displayed counters, and selecting the desired time base. To eliminate unintended operational interference, the computer can be in remote mode with all front panel controls disabled. With the CCNIM option, the computer can read the A and B counts, preset values, and which counter is being displayed. The CCNIM option can directly drive printers with RS-232-C ports.

    The inputs to Counters A and B can be individually selected as positive or negative sensing inputs by changing the input polarity jumpers on the counter printed circuit board (PWB). The negative input mode is designed to accept NIM standard fast negative logic pulses with a fixed threshold of -250 mV over a 50Ω input impedance. The negative input can handle count rates up to 100 MHz. Positive input mode can accept count rates up to 25 MHz on 1000Ω input impedance. To increase flexibility in positive input mode, both counters contain precision discriminators. The discriminator threshold can be set from +100 mV to +9.5 V using the front-panel, 25-turn trimpot. The threshold can be adjusted to suit the amplitude of a specific logic pulse source or used as a precision integral discriminator on analog pulses. For the latter application, the discriminator's TTL logic output is a test point on the front panel. These outputs can be used to trigger the oscilloscope when viewing analog signals at the oscilloscope's counter input. The oscilloscope trace will show the signal counted by the Type 994, allowing the threshold to be adjusted accordingly.

    All frequently used functions are conveniently accessible via the front panel. Count, stop and reset functions can be manually controlled via three buttons. When the Model 994 is enabled for counting, the door LED will illuminate. Time base button selects 0.01 second, 0.01 minute or external time base. In external mode, the preset counter counts events at the counter A input. The "Display" button switches the display to display the contents of counter A, the preset stop value, or the contents of counter B. To change a preset, you must first select the preset mode via the Display button. The Preset Select button can then be used to select M, N or P for adjustments. Use the "Preset Advanced" button to change the value of M, N or P. There are LED indicators on the display to indicate whether M, N, or P has been selected, to warn when an overflow occurs in Counter A or Counter B, and to indicate when the computer in remote mode should disable the front panel controls. The Dwell knob adjusts the display's dwell time from 1 second to 10 seconds when the Model 994 is in automatic recirculation mode.

    The counting function of the entire module can be disabled by holding the "enable" input below +1.5 V using an external signal source. The door LED will then turn off. If counting mode is activated, an open circuit at the Enable input or >+3 V allows the instrument to start counting. The interval output of another ORTEC timer can perform this function to synchronize the Model 994's count with another timer. The interval outputs of all ORTEC timers provide nominal +5 V when counting and <+0.5 V when counting is disabled.

    The A and B counter inputs can be independently gated via the Gate A and Gate B inputs on the rear panel. The interface connector for the RS-232-C option is located on the rear panel. Each counter has a dedicated rear panel output for signal overflow. Counting these overflows on another counter extends the counting capacity of the Model 994.

    The Model 994 is powered by ±12 V and +6 V supplies from the standard NIM power box. For power boxes that do not include a +6 V power supply, the internal +6 V power supply option is available. This option is field installable and draws power from the 117 V AC power cord in the power box.

  • Specifications +


    Performance

    Counting capacity

    8bit decimal, the counting range of both counters is0Arrive99,999,999。

    Count rate

    Negative input is100 MHz, the positive input is25 MHz。

    clock

    10 MHzClock, minimum preset or display interval is0.01seconds or0.01minutes. The nominal value of synchronization error is100 ns. when choosingExt(External) mode also accepts input from the counterAInput terminal (In A) external input.

    clock inaccuracy

    in0to50°CThe operating temperature range ≤±0.0025%。

    Default time/count

    When the preset value is reached on the blind preset registerMN X 10P, the module will stop counting.MandNYes0Arrive6numbers between. Use0.01seconds time base, you can use0.01Arrive990,000Preset time in seconds range. Use0.01Minute time base can be used0.01to990,000Preset time in minutes. inExtIn time base mode, you can use1Arrive99,000,000Preset count within range.

    positive input discriminator

    25The circle trimmer potentiometer is available at+100 mVto+9.5 VAdjust the threshold within the range.

    Pulse pair resolution

    Negative input<10 ns;positive input<40 ns。


    indicator

    Counter display

    8Bit7segmentLEDDisplay with leading zero suppression function. When displaying time, include the2number of digits.

    Overflow indicator light

    When the correspondingAorBcounter exceeds its8digit decimal capacity, marked withOvfl AandOvfl BofLEDThe indicator light will light up. The indicator light remains on until reset.

    M、NandPindicator light

    3aLEDIndicators help select presets. After activating the preset display function, the "Select" button can choose which of them to light up.LEDindicator light. when one ofLEDWhen lit, the Advanced button can be used to increment the preset value numerically.

    show

    3respectively marked withA、Band "default"LEDThe information shown in the counter display will be indicated. by repeatedly pressingDisplay(display) button until desiredLEDThe indicator light lights up and the counter can be displayedA, counterBvalue or default value.

    time base

    3aLEDThe selected time base source will be indicated. By pressing the time base button repeatedly, you can select0.01seconds,0.01minute or external mode

    door

    singleLEDUsed to indicate that counting is enabled for the entire instrument. to open the doorLEDlights up, the module must be put into counting mode (manually or via the interface option) and the "Enable" input must be above+3 V, and the preset stopping conditions must not be reached.

    remote

    marked withRemof singleLEDused to indicate994The model is under computer control, with all front panel controls disabled. This mode consists ofENABLE_REMOTECommand settings.


    control

    show

    The button can be selected in8Counter shown on decimal displayAorBcontent or default value. Press the button repeatedly toA、Band presetLEDChoose between the three options indicated.

    Select

    Buttons display selections for preset valuesM、NorPNumbers. Press the button to light upLEDChoose between the three options indicated. The Select button is only active when the Display button has Preset mode selected.

    Advanced

    Each time the Advanced button is pressed, the button increments by a preset number selected by the Select button.MandNThe range of numbers is0Arrive9。PThe range of numbers is0Arrive6. The Advanced button is only available when the Display button has Preset mode selected.

    time base

    Press this button repeatedly to0.01seconds,0.01minutes andExtChoose between three time base options to determine the time base source for the preset register.

    stop

    This button stops counting in all parts of the instrument.

    reset

    Pressing this button resets both counters to zero count and extinguishes both overflow lights. It also clears any counts accumulated in the blind preset counter but does not change the selected preset value. When the module is powered on, it automatically resets.

    count

    Pressing this button enables counting conditions for the entire instrument, provided that the "Enable" input is not lower than+1.5 Vand has not reached the preset value.

    Threshold adjustment (AandB)

    mounted on the front panel25Circle trimmer potentiometer adjustable counterAandBpositive input threshold. The range is+100 mVto+9.5 V. Adjacent test points provide the discriminator'sTTLLogic signal output for adjustment with an oscilloscope.

    stay

    A circle of potentiometers on the front panel, with a counterclockwiseOn/Offswitch. in1Arrive10Adjust the display dwell time within the nominal range of seconds. When the instrument is in recirculation mode, a dwell time occurs after the preset value is reached. Turning the switch off in the counterclockwise position selects single cycle mode. If the print loop option is used, the Dwell control is disabled when the print loop controller is active and controls the dwell time.

    Input polarity jumper

    located on the printed circuit board (PWB) on the two jumpers can beIn AandIn BInput selects the desired input polarity.P =Right,N =Negative.

    Acounter/
    timer jumper

    located inPWBtwo-position jumper on. In the counter position, the counterAAlways count and show connections toIn Aevents. When set to the timer position, if you select0.01seconds or0.01minute time base, counterAThe time will be counted and displayed. If you chooseExttime base, counterAwill count and display fromIn Aevents.

    Bcounter/timer jumper

    Bcounter/timer jumper located inPWBtwo-position jumper on. In the counter position, the counterBAlways counts and displays fromIn Bevents. In the timer position, if selectedExttime base, counterBwill count and0.01Display time in seconds intervals. If you choose0.01seconds or0.01minute time base, counterBwill count and display fromIn Bevents.

    doorA(live time/standard) jumper

    installed inPWBtwo-position jumper on. In standard position, from rear panel doorAThe connector signal will be gated fromIn AConnector events. In live position, from doorAThe connector signal will be gated10 MHzclock to form a live clock.

    1cycle/Recycle

    can passRS-232-Con the interface board8needleDIPswitch selection1Sub-circulation or recirculation mode. When994Recirculation mode can be used if the computer is able to respond with data transfer when the preset value is reached. After reaching the preset value,994The type latches its data into the buffer, resets the counter, and begins the next counting interval. This process takes approx.50 μs. The computer reads the data in the buffer before the end of the next counting interval. in1In secondary cycle mode,994The type simply stops counting when a preset value is reached and waits for further commands.


    Input

    IN A

    The use of this input is subject toAcounter/Effect of timer jumpers.

    positive input

    counterAfront panelBNCConnector accepts positive unipolar signals; minimum width is above threshold,50% duty cycle when20 ns. Thresholds are available via the front panel25circle trimmer potentiometer in+100 mVto+9.5 VEnter within the scope
    Make adjustments.Zin =1000 Ω to ground; DC coupled.

    Negative input

    Changing the input polarity jumper position on the counter board is optionalNIMStandard fast negative logic input designed to accept-600to-1800 mVpulse, with a fixed discriminator threshold of-250 mV。Zin =50Ω; DC coupled. The minimum pulse width above threshold is4 ns。

    In B

    withIn ASame but it feeds the counterB. The use of this input is subject toBcounter/Effect of timer jumpers.

    enable

    front panelBNCInput connector acceptsNIMStandard slow logic pulses to control counting conditions across the module. If the instrument is in counting mode and the preset value has not been reached, then>+3 Vlevel or open circuit will allow counting;<+1.5 VCounting will be disabled. The driving source must be able to absorb the5 mApositive current; the input terminal is protected to+25 V。

    doorA

    rear panelBNCInput Connector AND GateBThe inputs are the same with the following exceptions. WhenPWBthe upper doorAWhen the jumper is set to the standard position, the doorAThe input will control the counterAinIn AThe count of events. by addingPWBdoorAMove the jumper to the active position, and the doorAThe input will also control10 MHzclock to form a resolution of100 nslive time clock. level>+3 Vor open circuit allows counting clock. level<+1.5 VUsed to disable the count clock during the dead time interval.

    doorB

    rear panelBNCConnector acceptsNIMStandard slow positive logic signal to control counterBcount in . level> +3 Vor open circuit allows counting;<+1.5 VCounting is prohibited; input terminals are protected to+25 V. The driving source must be able to absorb the5 mAof positive current.


    Output

    interval

    front panel outputBNCThe connector provides a positive level during the count interval. When counting is enabled, the level is nominally+5 V;When counting is disabled, the level<+0.5 V。Zo~30 Ω。

    OVFL A

    When the counterAoverflow its8When the capacity is decimal, the rear panel outputBNCConnector providedNIMStandard slow positive logic signal. The nominal amplitude of this signal is+5 V;The width is approx.20 μs。

    OVFL B

    rear panel output andOvfl ASame, but it monitors the counter fromBof overflow.


    interface

    serial

    when insertingRS-232-Coption board, it will provide a rear panel25Pin GongDtype connector, included for standardRS-232-CAll signals for communication. It also contains for20 mAInterface for current loop communication. Field installableRS-232-COptions allow computer control of the following functions: count, stop, reset, remote, set presets, select displayed counters, and select desired time base. In remote mode, the computer can disable all front panel controls. Computer can read:AandBCount, preset value, and which counter is being displayed.


    electrical and mechanical

    Required power supply

    Basic model994Comes with ±12 Vand+6 Vpower supplyNIMThe power box gets the power. For not providing+6 VofNIMPower box, optional internal+6 Vpower supply. This option is field installable and installs from the power box117 VGet power from the AC power cord. If installed internal+6 Vpower supply, please refer to Chapter4Power requirements in column, p.3Column can be ignored

    Required power supply

    Powered by power box

    internal+6 Vpower supply117 V AC

    +12 V

    -12 V

    +6 V

    Basic model994

    35 mA

    115 mA

    1300 mA

    110 mA

    Model994addRS-232-COptions

    54 mA

    130 mA

    1800 mA

    145 mA

    weight

    Net weight 2.4Kilogram (5.2pounds).Shipping weight 3.7Kilogram (8.2pounds).

    Size

    NIMStandard double wide module,6.90 x 22.13cm (2.70 x 8.714inches) front panel, conforming toDOE/ER-0457Trequirements.


  • Ordering information +


    Model Description
    994 Basic module with no plugin options.
    99X-1 RS-232-C interface option (cable not included).
    99X-4 Internal +6 V power option.
    C-75 Female-to-female RS-232-C cable (3 meters long).
    C-80 Male to female RS-232-C extension cable (3 meters long).