Brief description:Can be used with scintillation detectors and proportional counters for counting, timing and energy spectrum analysis. Selectable shaping times (0.5, 1.5 and 3.0s). High count rate capability. Gated active baseline restorer. Selectable window range. Integration/Window mode. ORTEC Model 590A amplifier and timed single channel analyzer includes a low noise shaping amplifier and a timed single channel analyzer.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC 590A Amplifier and Timing Single Channel Analyzer (SCA)
  • Can be used with scintillation detectors and proportional counters for counting, timing and energy spectrum analysis
  • Selectable shaping times (0.5, 1.5 and 3.0 μs)
  • High count rate capability
  • Gated Active Baseline Restorer
  • Optional window range
  • Points/window mode

The ORTEC Model 590A Amplifier and Timing Single Channel Analyzer consists of a low noise shaping amplifier and a timing single channel analyzer.
  • information +

    • Download link 590A Brochure
    • Download link 590A Brochure (A4)
    • Download link 590A Manual
  • More information +


    The amplifier uses active filter shaping (0.5, 1.5 and 3.0 μs shaping times) and can be used with various types of radiation detectors. It is particularly suitable for use in conjunction with proportional counters and scintillation detectors commonly used in X-ray, nuclear spectroscopy measurements, X-ray diffraction and Mössbauer experiments. High amplifier gain improves the performance of proportional counters because they can be used at lower operating potentials, thereby improving gas gain versus count rate stability. The amplifier's short resolution time ensures high count rate capability without sacrificing the energy resolution of the proportional counter.

    The amplifier features a switch-selectable single output for unipolar or bipolar pulse shaping. The unipolar output is suitable for systems that can maintain DC coupling from the Model 590A to the analyzer for spectral analysis. A baseline restorer (BLR) circuit is included in the amplifier to improve performance at all count rates. Baseline correction is only applied in the intervals between input pulses, and in addition, the discriminator level used to identify the input pulses is automatically adjusted. Unipolar output DC levels range from -5 mV to +5 mV. This output allows the use of the analyzer's direct-coupled input, minimizing interfacing issues.

    The timed single-channel analyzer (TSCA) in the Model 590A is DC-coupled to maintain peak values within the adjustment window without drift due to changes in count rate. This enables stable operation with narrow window widths over a wide range of count rate variations, such as those commonly found in X-ray diffraction studies. The low level can be adjusted via the front panel controls or set via an external voltage.

    The TSCA output occurs approximately 500 ns after the peak value of the amplifier output signal. This signal has very little wander over a wide input amplitude range, making the Type 590A suitable for slow coincidence or gating applications.

    The External Low Level (Ext LLD) input of the Type 590A can be used in conjunction with an external voltage to set the low level. It can also be used with slowly varying voltages to vary the low level based on time or other measured parameters.

  • Specifications +


    amplifier

    Performance

    plastic surgery

    When the peak time is equal to2.2τ,0.1% level when the pulse width is equal to the peak time4times, it is semi-Gaussian in all ranges. Bipolar crossover equals1.5τ。

    gain range

    fromX5ArriveX1250Continuously adjustable.

    integral nonlinearity

    Use1.5 μsDuring plastic surgery<±0.05%。

    noise

    Use3 μsWhen unipolar shaping is performed, it is referred to the input terminal<5 μV rms, as well as using1.5 μsWhen shaping, ≤7 μV, both gain ≥100。

    temperature instability

    Gain ≤±0.0075%/°C,0to50°C。
    DC level ≤±50μV/°C,0to50°C。

    Count rate stability

    60Cosource1.33-MeVThe gamma ray peak is at the end of the analyzer range85%, usually offset<0.02% when its input count rate is in use1.5-μsIn the case of plastic surgery, from1000Arrive50,000count/When seconds change, itsFWHMwiden<10%. amplifier at count rates exceeding75,000count/seconds will maintain the baseline reference.

    Overload recovery

    When using gain, in2.5within a non-overload unipolar pulse width fromX300Overload returns to rated output2Within %; bipolar pulse fromX500Recovery from overload is the same.

    baseline restorer (BLR)

    A gated active baseline stabilizer with automatic threshold circuitry provides the threshold level as a function of signal noise to the baseline restorer discriminator.


    control

    Coarse gain adjustment

    A six-position switch selects the amplifier's coarse gain coefficient; the coefficients are10、20、50、100、200and500。

    Fine-tune gain

    Single turn potentiometer for direct reading, trim gain factor available from0.5Arrive2.5Adjustments are made continuously.

    PZ ADJ

    Amplifier shaping can be matched to the preamplifier's decay time via front panel screwdriver adjustment; available from30 μsto ∞ to adjust the preamplifier’s decay time. Factory setting is50 μs。

    plastic surgery

    Three three-digit printed circuit boards (PWB) switch, easily accessible via the side panel to select0.5、1.5and3.0 μsplastic surgery time.

    POS/NEG

    A front panel toggle switch selects the input circuit for either polarity of the preamplifier input pulses.

    UNI-BI

    Front panel toggle switch selects unipolar or bipolar output shape.









    Input

    AMPinput

    BNCFront and rear panel connectors accept positive or negative pulses, selected with a front panel toggle switch, with rise times ranging from10to650 ns, the decay time is30 μsto ∞;Zin =1000 Ω, DC coupled; linear value,2 V;value,20 V。




    Output

    AMP

    front panelBNC,Zo <1Ω. With short circuit protection function;0to+10 VFull-scale linear range in time; active filter shaping and DC recovery for unipolar output; DC levels0to±5 mV。




    Preamp power supply

    rear panel standardORTECpower connector;Amphenol 17-10090or equivalent, with all standardsORTECPairing of onboard and offboard power cords on the preamplifier.




    Timed Single Channel Analyzer


    Performance

    Enter dynamic range

    200:1。

    Pulse pair resolution time

    The shaping time is0.5 μsWhen, the minimum pulse pair resolution time ≤2 μs。

    Output timing

    After the amplifier output pulse peak ≅500 ns。

    Time offset and pulse height (swimming)

    in0.5 μsUnder shaping time, for50:1The output amplitude changes, swimming<±10 ns。

    Threshold Temperature Instability

    ≤± of full scale0.01%/°C(1 mV/°C)。0to50°C, useNIM Aclass power supply (reference-12 V)。

    Non-linearity of the discriminator

    ≤ ± of the full scale (integral) of both discriminators0.25%。

    Window width invariance

    in0to10 VWithin the linear range of the change<full scale window width0.1%。

    Minimum input threshold

    For low-level discriminators,50 mV。

    EXT LLD

    When the low-level reference mode switch mounted on the rear panel isExtWhen up, the rear panelBNCThe connector accepts low-level bias (the0to-10 Vinput corresponds to the low-level discriminator setting0to+10 Vsignals within the range). Input impedance2000 Ω。


    control

    low level

    front panel10coil potentiometer, from0Arrive+10 VAdjustable; when the rear panelLL RefThe mode switch is set toIntWhen , the threshold of the low-level discriminator can be set. When the rear panelLL RefThe mode switch is inExtposition, this control has no effect.

    window

    on the front panel10turn precision potentiometer for adjusting analyzer window width (selected by internal jumpers0to10 Vor0to1 V. Factory setting is0to10 V)。

    INT/window

    Front panel toggle switch selects operating mode.
    • window LLSet the baseline level (0Arrive10 V), the window control sets the window width to0Arrive1 Vor0Arrive10 Vbetween.
    • Int PointsLLSet individual discriminator thresholds (0Arrive10 V), the window controls are disabled.

    Low level reference

    A rear panel-mounted toggle switch selects the source of low-level bias.IntPosition selection front panel controls;ExtSelect low-level bias via the rear panel connector.


    Input

    SCA

    Internally connected to amplifier output; impedance is1000 Ω。

    EXT LLD

    0to-10 Vinput,2000 Ω input impedance; rear panel connector.





    Output

    SCA OUT

    Front and rear panelsBNCConnectors are provided with nominal+5 V, width500 nsofNIMstandard output; usually50Ω output impedance.

    DISC OUT

    rear panelBNCConnectors are provided with nominal+5 V, width500 nsofNIMstandard output; usually50Ω output impedance. The output occurs when the leading edge of the linear input crosses the window threshold.





    electrical and mechanical

    Required power supply

    +24 V, 35 mA; –24 V, 25 mA; +12 V, 115 mA; –12 V, 85 mA。

    weight

    Net weight 1.3Kilogram (3.0pounds). Shipping weight 2.25Kilogram (5.0pounds).

    Size

    single widthNIMStandard module3.43 X 22.13cm (1.35 X 8.714inches), consistent withDOE/ER-0457Trequirements.